8 Dismounting
General:
-
Dismounting may only be carried out by qualified personnel.
-
Make sure that only personnel taking care of the mounting/dismounting is present at the mounting
place. Keep other persons at a distance, for example by using a safety ribbon
-
When dismounting the device, make sure there is enough light.
-
Make sure that you use the right tools to remove the tension of the springs and make sure you are
standing firmly
Procedure:
Block the shaft with the pinchers.
Secure the door in such a way that it cannot come up. Do so for instance by fastening pinchers to the vertical
tracks.
IMPORTANT: There is much strain on tensioned springs; proceed carefully at all times and use tensioner
bars that fit well and that are kept in good condition (12025)
1)
Insert the first tensioning bar in the spring fitting.
2)
Keep the first tensioning bar firmly in your hands and carefully loosen the bolts on the spring fitting and
take over the spring tension.
3)
Now place the second tensioning bar in the next hole of the sping fitting and carefully release the
spring. The spring is basically released from top to bottom.
4)
Put the first tensioning bar back in the spring fitting and release.
5)
Repeat steps 3 - 4 until the spring is released.
6)
Repeat steps 1 - 4 with the other spring.
7)
Loosen the bolts of the cable drums and remove the steel cables from the cable drums.
8)
Dismount the shaft with springs
9)
Loosen the bolts and nuts from the coupling of the synthetic curve with horizontal track.
10)
Dismount the suspension and slide the horizontal track out of the plastic curve.
11)
Dismount the panel sections from top to bottom by loosening the roller carriers and intermediate
hinges.
12)
Dismount the synthetic curve.
13)
Dismount the vertical angle.
8.1 Removal
All parts of the garage door are easy to separate and to recycle.
Separate all elements after dismantling.
Note: The material is only recyclable if separated
Turn in the materials at the authority responsible for the treatment of separated materials.
10 Your Manufacturer