AuroraDMX Control
6
DMX-Addressing
The DMX-Starting address is adjustable via the DIP-Switches 1-9.
Switch 1 has the valency 2
0
(=1), switch 2 has the valency 2
1
(=2) and so on, finally
switch 9 has the valency 2
8
(=256). The sum of the switches showing ON, represents
the start address.
Switch 10 is reserved for demo programs and must show OFF during the DMX-
Operation.
LED-Display-Codes
The integrated LED is a multifunctional display.
In the normal operation mode the LED lights non-stop.
Furthermore the LED signals the operation status. In this case, the LED lights up in
short pitches and then turn into off mode. The number of flashing signals is equal to
the number of the error status:
Error-
Status
Error
Description
1
No DMX-Signal
No DMX signal is detected
2
Addressing error
Please check, if a valid DMX-Start address is
adjusted via the DIP-Switches
3
DMX-Signal error
An invalid DMX-Input signal is detected.
Swap the signal lines on pin 2 and pin 3 or use
twisted connection cable.
1
2
4
8
1
6
3
2
6
4
1
2
8
2
5
6