AuroraDMX Control
12
RDM
(Firmware V1.1 or higher is needed)
RDM is the short form for
R
emote
D
evice
M
anagement.
As soon as the device is within the system, device-dependent settings can be occur
remotely via RDM command due to the uniquely assigned UID. An direct access to
the device is not necessary.
If the DMX start address is set via RDM, all address switches at the
AuroraDMX Control must be set to OFF ! A DMX start address set by the
address switches is always prior !
This device supports the following RDM commands:
Parameter ID
Discovery
Command
SET
Command
GET
Command
ANSI/
PID
DISC_UNIQUE_BRANCH
E1.20
DISC_MUTE
E1.20
DISC_UN_MUTE
E1.20
DEVICE_INFO
E1.20
SUPPORTED_PARAMETERS
E1.20
PARAMETER_DESCRIPTION
E1.20
SOFTWARE_VERSION_LABEL
E1.20
DMX_START_ADDRESS
E1.20
DEVICE_LABEL
E1.20
MANUFACTURER_LABEL
E1.20
DEVICE_MODEL_DESCRIPTION
E1.20
IDENTIFY_DEVICE
E1.20
FACTORY_DEFAULTS
E1.20
DMX_PERSONALITY
E1.20
DMX_PERSONALITY_DESCRIPTION
E1.20
SERIAL_NUMBER
1)
PID:
0xD400
1) Manufacturer depending RDM control commands (MSC - Manufacturer Specific Type)