ArtNet-LED-Dimmer 4
MK2
7
In the ArtNet Settings the settings for the Subnet, Net and Port (Universe) are
available.
The DMX-Start address specifies the channel in the DMX-Universe on which the
LED-Outputs are to be addressed. The DMX-Start address is output 1 and following
addresses are outputs 2-4.
The Master Dimmer is to activate if all outputs should be dimmed simultaneously
with an additional ArtNet-Channel. This is possible in the StandAlone-Operation as
well as in the ArtNet-Operation. Thereby the Master-Channel is the first one.
An adjustable Default value specifies which value is outputted from the Master
dimmer after turning on the Dimmer.
StandAlone allows the running without connection to an ArtNet-Control. The set
program is executed by turning on the device.
If data are received from an ArtNet-Control for one output with a value higher 0, so
the program shut down automatically and the outputs assume the values specified by
the received ArtNet-Signal.
Restart determines after which time the StandAlone-Program will be started, if no
ArtNet-Signal is received.
Enable ArtNet-Master for StandAlone serves for outputting the StandAlone-
Programs via ArtNet. The data beginning with the DMX start address is sent
broadcast to the ArtNet-Devices. The Net/SubNet/Universe settings are used for this
transfer. So it is possible to run several ArtNet-LED-Dimmer in sync.
A user defined color gradient can be used with User Color. The User Color Setup is
described on the following pages.
If the option LED indicator auto off is activated, the LEDs at the device are shut
down after 10 minutes of operation with a permanent net work connection.
SAVE stores the configuration respectively restores the Factory Settings.
Using other IP-Addresses
The ArtNet-LED-Dimmer 4
MK2
can work with any other IP-Addresses.
You can use for your net work the usual IP-Adresses 192.168.1.x .
In this case set the net mask to 255.255.255.0 .