Data sheet 

 
Power supply: 

12-24V DC 

 

The supply voltage must correspond to the voltage for the 

 

LED stripe ! 

 
LED-Voltage: 

12-24V DC  (no AC voltage !) 

 
Ethernet: 

RJ45 

 
Protocol: 

Art-Net™ or 

 

DMX4ALL Commands 

 
LED-Connection: 

4x (R/G/B + W) max. each 10A 

 

in sum 16A with common anode (+) 

 

4 PWM-Signals with 256 steps 

 
PWM-Frequency: 

250 Hz 

 
Dimensions: 

115mm x 54mm x 23mm 

 
 
 
 
 

Delivery 

1x 

ArtNet-LED-Dimmer 4 

MK2

 

1x 

Screw clamps 2pin / RM5 

1x 

Screw clamps 5pin / RM5 

1x 

1m RJ45 Net work cable 1:1 

1x 

Quick guide german and english 

 
 
 
 
 

LED-Displays 

 
LED green  The green LED flashes, if no Ethernet-Connection is available and 

lights permanently, if an Ethernet-Connection is available.   

 
LED yellow  The yellow LED lights up as soon as data are received.  
 

Содержание ArtNet-LED-Dimmer 4 MK2

Страница 1: ...ArtNet LED Dimmer 4 MK2 User manual Art Net Designed by and Copyright Artistic Licence Holdings Ltd...

Страница 2: ...fast and uncomplicated setting of all parameters No special software is necessary a standard web browser is enough So the configuration is possible every time from PC Smartphone or tablet For an easy...

Страница 3: ...6A with common anode 4 PWM Signals with 256 steps PWM Frequency 250 Hz Dimensions 115mm x 54mm x 23mm Delivery 1x ArtNet LED Dimmer 4 MK2 1x Screw clamps 2pin RM5 1x Screw clamps 5pin RM5 1x 1m RJ45 N...

Страница 4: ...ArtNet LED Dimmer 4 MK2 4 Connection With RGB LED Stripe and LED Stripe white With 4 single color LED Stripes...

Страница 5: ...IP Configurator The ArtNet LED Dimmer 4 is shown in the list Select the entry click Enter the new IP and net mask Click SET Set the IP with web browser The assigned IP Address within the delivery stat...

Страница 6: ...can occur clearly within the net work Use in accordance to the ArtNet Specifications the IP Address 2 x x x or 10 x x x The Netmask is according to the ArtNet Specifications 255 0 0 0 TIP Any other I...

Страница 7: ...he program shut down automatically and the outputs assume the values specified by the received ArtNet Signal Restart determines after which time the StandAlone Program will be started if no ArtNet Sig...

Страница 8: ...the addresses is as follows OUT1 OUT2 OUT3 OUT4 It is also possible to dim the replayed StandAlone Programs respectively the user defined color changes The Default Value specifies the value the Maste...

Страница 9: ...ms User Color allowing to create free defined color replays up to 16 steps The delivery status has predefined programs for the operation with RGB LED Stripes All programs User 1 User 10 are editable f...

Страница 10: ...R STEP EDITOR is shown for editing the user defined color changes program In Step List Overview a table shows the 16 current steps Step1 up to Step 16 Not assigned steps are not shown in the table Eac...

Страница 11: ...p to Channel 4 the brightness values 0 255 for the outputs 1 up to 4 is entered A value of 255 complies with 100 By clicking Add the step after the last used step is added and transferred to the table...

Страница 12: ...se select the Smart Control page Moving the mouse over the color circle the color is transferred to the sliders and to the value display Clicking left the current color value is transferred to the LED...

Страница 13: ...e Google Play Store and can be installed with each Smartphone or Tablet with Android 4 0 or higher After starting the app for the first time the ArtNet LED Dimmer 4 IP must be entered in the Main Sett...

Страница 14: ...l opens With this function the ArtNet LED Dimmer can be used in a live operation To set the playback rate and the brightness two sliders Speed Brightness are available Edit programs To edit a program...

Страница 15: ...D Dimmer So the set light picture can be checked The Fade Time and Wait Time specify the fade time and the wait time for each step in seconds At the end of the list a step with the current values is a...

Страница 16: ...the internal storage Internal Memory as well as the external storage from a SD Card External Memory can be used By tapping to Internal Memory respectively External Memory a storage location is select...

Страница 17: ...sign an attractive surface with easy possibilities for color settings Recommended for installations with one ArtNet LED Dimmer Light Remote fee required App for easy remote control of Art Net Installa...

Страница 18: ...r 4 MK2 can also be operated at a WLAN Router Access Point or at a WLAN Bridge Running at WLAN Router Access Point Running at WLAN Bridge 1 Smartphone TabletPC 2 WLAN Router Access Point 3 ArtNet LED...

Страница 19: ...ask are reset A return can t take place always If necessary please set the IP again see Set the IP with IP Configurator or Set IP with web browser Restore the delivery status via DMX4ALL LAN Updater T...

Страница 20: ...ately Select the ArtNet LED Dimmer 4 from list Click Firmware Update Select and confirm Firmware File bin Please wait until the update has finished If an error occurs you can begin from the start anyt...

Страница 21: ...ArtNet LED Dimmer 4 MK2 21 Accessory RGB LED Stripe 5m LED Stripe white Power supply 12V 5A...

Страница 22: ...oard the board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and underst...

Страница 23: ...d using electronic systems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely It is pointed out that...

Отзывы: