DMX-RELAIS 8
14
Personality 3: Hysteresis 100/150
In this operation mode, the relays switch of each other independently, each via one
DMX channel.
The switching threshold (Hysteresis) is 100/150. That means that the relay is
switched off when the DMX value is 100 or less and that the relay is switched on
when the DMX value is 150 or greater.
DMX
Channel
DMX
Value
Function
1
0-100
Output 1 OFF
101-149
Output 1 NO ACTION
150-255
Output 1 ON
2
0-100
Output 2 OFF
101-149
Output 2 NO ACTION
150-255
Output 2 ON
3
0-100
Output 3 OFF
101-149
Output 3 NO ACTION
150-255
Output 3 ON
4
0-100
Output 4 OFF
101-149
Output 4 NO ACTION
150-255
Output 4 ON
5
0-100
Output 5 OFF
101-149
Output 5 NO ACTION
150-255
Output 5 ON
6
0-100
Output 6 OFF
101-149
Output 6 NO ACTION
150-255
Output 6 ON
7
0-100
Output 7 OFF
101-149
Output 7 NO ACTION
150-255
Output 7 ON
8
0-100
Output 8 OFF
101-149
Output 8 NO ACTION
150-255
Output 8 ON
For this operation mode choose via RDM the Personality 3.