6
714N-POE Installation and Programming Guide | Digital Monitoring Products, Inc.
ADDRESSING THE 714N-POE
Note:
For XR Series Version 192 firmware and lower, the 714N-POE must be programmed as a
network door. In Version 193 firmware and higher, the 714N-POE should be programmed as a
network expander. Refer to the XR Series panel programming guide (
Keypad Bus Addresses
DMP XR150/XR550 Series panels use keypad bus addresses 1 through 16. Each keypad bus address
can accommodate one 714N-POE. A module with an address of 2 on the keypad bus would represent
Door 2 and zones 21-24. A module with a keypad address of 14 would represent Door 14 and zones
141-144.
AX-Bus Addresses (XR550 only)
DMP XR550 panels are capable of access control expansion using any of the five AX/LX-Bus headers
(AX/LX500, 600, 700, 800, and 900). The 714N-POE takes up an AX-Bus address that can no longer
be used for a door. The 714N-POE module shares AX-bus addresses with the 734N, which limits the
number of devices to 16. A module with an address of 501 on AX500 would represent zones 501-504.
A module with an address of 505 on AX500 would represent zones 505-508. A module with an
address of 701 on AX700 would represent zones 701-704.