background image

Digital Monitoring Products, Inc.     |     714N-POE Installation and Programming Guide  

7

Setting the 714N-POE Addresses

Only valid zone numbers can be assigned 714N-POE in device setup. For complete keypad and AX-
Bus address mapping, see the chart below.

Table 1: Device Addresses and 714N-POE 

Zone Numbers

DEVICE

ZONES

DEVICE

ZONES

DEVICE

ZONES

DEVICE

ZONES

DEVICE

ZONES

DEVICE

ZONES

1

11-14

501

501-504

601

601-604

701

701-704

801

801-804

901

901-904

2

21-24

505

505-508

605

605-608

705

705-708

805

805-808

905

905-908

3

31-34

509

509-512

609

609-612

709

709-712

809

809-812

909

909-912

4

41-44

513

513-516

613

613-616

713

713-716

813

813-816

913

913-916

5

51-54

517

517-520

617

617-620

717

717-720

817

817-820

917

917-920

6

61-64

521

521-524

621

621-624

721

721-724

821

821-824

921

921-924

7

71-74

525

525-528

625

625-628

725

725-728

825

825-828

925

925-928

8

81-84

529

529-532

629

629-632

729

729-732

829

829-832

929

929-932

9

91-94

533

533-536

633

633-636

733

733-736

833

833-836

933

933-936

10

101-104

537

537-540

637

637-640

737

737-740

837

837-840

937

937-940

11

111-114

541

541-544

641

641-644

741

741-744

841

841-844

941

941-944

12

121-124

545

545-548

645

645-648

745

745-748

845

845-848

945

945-948

13

131-134

549

549-552

649

649-652

749

749-752

849

849-852

949

949-952

14

141-144

553

553-556

653

653-656

753

753-756

853

853-856

953

953-956

15

151-154

557

557-560

657

657-660

757

757-760

857

857-860

957

957-960

16

161-164

561

561-564

661

661-664

761

761-764

861

861-864

961

961-964

Содержание 714N-POE

Страница 1: ...INSTALLATION AND PROGRAMMING GUIDE 714N POE Network Zone Expander Module...

Страница 2: ......

Страница 3: ...POE 6 Program the 714N POE Module 8 Program Start Display 9 Initialization Option 9 Initialize Confirm Option 9 Communication Menu 9 TABLE OF CONTENTS 714N DHCP 10 714N IP Address 10 Subnet Mask 10 Ga...

Страница 4: ...odule or from XR150 XR550 panels The 714N POE Network Zone Expander Module allow you to add 4 zones to XR150 XR550 Series panels using IP network capability The 714N POE is compatible with 1k to 10k r...

Страница 5: ...2 714N POE Installation and Programming Guide Digital Monitoring Products Inc PCB FEATURES DC INPUT ZONES INDICATOR LEDS Figure 1 PCB Features POWER OUTPUT...

Страница 6: ...k also contains multiple mounting holes that allow you to mount the module on a single gang switch box 1 Remove the circuit board from the plastic housing by loosening the clips on one side and gently...

Страница 7: ...module communicates AES encrypted TCP with panels that have network installed Two LED s are located on the ethernet jack The green LED indicates data sent to the panel The yellow LED indicates the sp...

Страница 8: ...inals provide a non powered Class B Style A zone The valid range of EOL resistors is 1k to 10k allowing for a wider range of takeovers Refer to the panel programming guide for programming instructions...

Страница 9: ...ule with an address of 2 on the keypad bus would represent Door 2 and zones 21 24 A module with a keypad address of 14 would represent Door 14 and zones 141 144 AX Bus Addresses XR550 only DMP XR550 p...

Страница 10: ...16 5 51 54 517 517 520 617 617 620 717 717 720 817 817 820 917 917 920 6 61 64 521 521 524 621 621 624 721 721 724 821 821 824 921 921 924 7 71 74 525 525 528 625 625 628 725 725 728 825 825 828 925 9...

Страница 11: ...tion must be performed with a keypad Afterwards device programming and 714N POE options may be programmed from the panel s programming interface The panel s programming overrides any programming perfo...

Страница 12: ...select key or area to enter the initialization menu INITIALIZE CONFIRM OPTION The module displays SURE YES NO for confirmation to clear the memory This is a safeguard against accidentally erasing the...

Страница 13: ...1 SUBNET MASK Enter the local subnet mask assigned to the module Default is 255 255 255 0 GATEWAY ADDRESS Enter the local gateway address of the module Default is 192 168 0 1 PANEL IP ADDRESS Enter th...

Страница 14: ...nel IP port cannot be the same as the panel network programming port Default is 2002 714N POE PASSPHRASE You must enter an 8 16 character alphanumeric passphrase to encrypt communication with the pane...

Страница 15: ...using the TCP IP protocol that remains open indefinitely No inbound communication is allowed This prevents a potential intruder from making any type of connection with the 714N POE through the network...

Страница 16: ...FICATIONS COMMERCIAL BURGLARY XR550 SERIES PANELS When using the zones of the 714N POE in a listed application place the module in a listed enclosure and connect a DMP Model 307 Clip on Tamper Switch...

Страница 17: ...ts Inc FCC Part 15 UNDERWRITERS LABORATORY UL LISTED 714N POE ANSI UL 294 Access Control System Units ANSI UL 609 Local Burglar Alarm Units And Systems ANSI UL 1076 Proprietary Burglar Alarm Units And...

Страница 18: ...y Power 8 5 VDC to 28 5 VDC if 12 VDC Current Draw Standby Alarm 75 mA at 12 VDC When powered from POE Standby Alarm 25 mA Output Voltage POE 12 VDC Maximum Power Draw POE 12 95 W Available Output Cur...

Страница 19: ...16 714N POE Installation and Programming Guide Digital Monitoring Products Inc...