27
DYN2MS-02F-0116A17
█
Reference Pulse Format
♦ Pulse + Direction
Forward Reference
Reverse Reference
PUL+
JP3-6
DIR+
JP3-4
PUL+
JP3-6
DIR+
JP3-4
♦ CW + CCW
Forward Reference
Reverse Reference
CW+
JP3-6
CCW+
JP3-4
CW+
JP3-6
CCW+
JP3-4
♦
A/B phase quadrature with 90° phase differential
Forward Reference
Reverse Reference
A+
JP3-6
B+
JP3-4
A+
JP3-6
B+
JP3-4
A Leads B
B Leads A
The DYN2 servo drive accepts FORWARD reference as CLOCKWISE motor shaft rotation as viewed from
motor shaft side.
4.1 Position Servo Mode