■ Servo Disable / Enable Timing
When using the ENA signal to disable the servo drive to coast the servo motor, do not cycle this input
rapidly ON/OFF. If the signal is cycled too fast, the servo drive will not have enough time to initialize the
control program during Enable and can cause unwanted or dangerous results. Ensure that in the control
program, the below timing is satisfied. Once Disabled, do not Enable the servo drive during motor coast or
any time motor shaft is rotating, make sure motor shaft is completely stopped before Enable.
3.2 Timing Chart
ENA
Command Reference Input
Pulse / Analog
ON
OFF
HIGH
LOW
20ms
Servo Enabled