![DMC Combine CALC-U-DRI II Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/dmc/combine-calc-u-dri-ii/combine-calc-u-dri-ii_owners-manual_2513628008.webp)
SENSOR INSTALLATION (continued)
2.
Mark the flighting that sweeps over the sensor hole and disassemble the auger tube
from the flighting.
3.
Locate the marks made on the flighting above the sensor hole and weld the flighting
to the auger shaft starting 3/8” beyond each end of the marks.
4.
Cut approximately six and one-half inches (6-1/2”) of flighting out between the
welds and smooth out any rough edges on the flighting ends and on the auger
shaft.
See Photo E. Notice that the flighting is removed all the way to the shaft.
Photo E
OPTIONAL
: The flighting cut out may be used to double the flighting
thickness on each side of the sensor opening. This is optional and
not required.
5.
Reassemble the auger tube and check to make sure that the flighting will not
hit the sensor blade, inserting the sensor gauge into the sensor hole and
rotating the flighting. The flighting should clear the gauge. If not, cut out
``
additional flighting.
6.
Insert the sensor into the tube and
secure in place with the hose clamp
provided.
See Photo F.
(Only one hose clamp is now used.)
Photo F
(New sensors have
one
clamp)