TROUBLE SHOOTING GUIDE (continued)

         PROBLEM

     PROBABLE CAUSE

SOLUTION

Red LED indicator

1.

Wiring error

1.

Check the 5

does not come on

wire connections

at moisture limit

on the terminal

setting

for the digital
panel meter

“AVG ON” LED

1.

Averaging switch

1.

Check  wiring

does not work

wired incorrectly

2.

Averaging switch not

2.

Relocate switch

in flow of grain

3.

Averaging switch bad

3.

Replace switch

“AVG ON” LED

1.

Object jammed on

1.

Remove object

stays on when

averaging switch

out of grain

Blowing the control

1.

DC power wires are

1.

The red wire

fuse (2 Amp AGC)

crossed

must be hooked
to positive 12 volts.
White is hooked to
ground.

2.

Sensor wires damaged

2.

Replace the

and shorted to ground

sensor and cable.

3.

Control board failure

3.

Replace the control
board

1.

Never unplug or plug in the circuit board with power on.

2.

Do not make field adjustments on the circuit board.  This is a factory adjustment only.

3.

On combines where the sensor is mounted in a horizontal tube, the sensor should
be removed from the auger tube and the grain cleaned out before storing the
combine between seasons.

4.

Contact your dealer or DMC if you have any questions on the operation or service
of your combine Calc-U-Dri Moisture Monitor.

TAKE TIME FOR PROPER INSTALLATION  ---  IT SAVES SERVICE CALLS!

14

Содержание Combine CALC-U-DRI II

Страница 1: ...OWNER S MANUAL COMBINE CALC U DRI II With Averaging PNEG 1138 PNEG 1138 Date 9 21 06...

Страница 2: ...ation 16 20 CAUTION BE A SAFE OPERATOR 1 Read and understand this Owner s Manual 2 Stop the combine threshing unit and engine before sampling adjusting or servicing Use caution when obtaining a sample...

Страница 3: ...oisture monitors and controls in the grain drying industry Your new Combine Calc U Dri was designed by DMC s engineers who also farm and utilize this equipment in their farming operations Since the Co...

Страница 4: ...ed A new average will auto matically begin if the AVG ON indicator is on 10 The averaging switch located in the path of the clean grain signals the Combine Calc U Dri II when switch is covered with gr...

Страница 5: ...to the chosen location and mark the mounting holes through the top of the box See Photo B Diagram 1 Note Six mounting holes are provided in the Combine Calc U Dri box Use two or four of the holes to...

Страница 6: ...ews for the panel or to attach a safety chain to insure that if the panel does become loose it will not obstruct operation of the combine 5 Select a location for the digital display such as the back s...

Страница 7: ...route the power supply wires See Photo C CONTROL BOX INSTALLATION continued Photo C SENSOR INSTALLATION 1 The sensor should be mounted in the clean grain auger tube in the combine grain hopper Use the...

Страница 8: ...See Photo E Notice that the flighting is removed all the way to the shaft Photo E OPTIONAL The flighting cut out may be used to double the flighting thickness on each side of the sensor opening This...

Страница 9: ...2 inch diameter drill bit for drilling the hole for the grommet Photo G New sensors have one clamp NOTE It is important when routing cable that it is attached securely against something so that the gr...

Страница 10: ...ram 3 Drill a 3 8 diameter hole and a 1 1 8 diameter hole 2 3 4 apart Attach bracket to the boot housing with 5 16 x 3 4 bolt lock washer and nut If bracket is too long to fit in housing cut off exces...

Страница 11: ...nd the bracket 5 Route the cable out of the hopper and to the cab using stick on clips and ties Use a grommet if a hole must be drilled for entry into the cab Route the sensor cable about ten inches t...

Страница 12: ...for a short period of time stop the combine Remember the cautions above 2 Collect a sample of grain from the very top layer of grain The grain that was being augered into the hopper when the digital p...

Страница 13: ...8 1 Box Bottom 11 602E201 1 Box Top 12 602E202 1 Box End 13 602E203 1 Box Hinge 14 602E309 1 Bracket Terminal Block 15 1EL2046 1 Grommet 16 MS0138 1 Plug 17 2EL0651 1 Switch DPDT 3 Pos 18 1EL0921 2 Kn...

Страница 14: ...or are very high but blade grain checks dry 2 Foreign object jammed 2 Remove on sensor 3 Offset accidentally 3 Readjust set too high 4 Sensor not grounded 4 Secure ground to the tube strap 5 Bad circu...

Страница 15: ...ation Moisture reading 1 Control board not 1 Replace control temperature reading functioning correctly board and moisture limit are all reading the same value Digitial display does 1 Broken wire or 1...

Страница 16: ...wire fuse 2 Amp AGC crossed must be hooked to positive 12 volts White is hooked to ground 2 Sensor wires damaged 2 Replace the and shorted to ground sensor and cable 3 Control board failure 3 Replace...

Страница 17: ...and grain condition log the offset value on the following chart for future reference A few grains and approximate offset values are already listed to assist with your initial calibration GRAIN TYPE O...

Страница 18: ...the intake housing 3 16 diameter and install 4 8 x 3 4 screws and nuts as studs in the up elevator side Place the steel plate spacer over the 8 screws nuts and assemble the intake housing to the elev...

Страница 19: ...41346 Auger motor mounting spacer 11 5041348 Auger sensor housing bottom R H 12 5041349 Auger sensor housing bottom L H 13 5041353 Auger sensor housing plastic spacer R H 14 5041354 Metering auger 15...

Страница 20: ...18...

Страница 21: ...19...

Страница 22: ...20...

Страница 23: ...LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION LOSS OF ANTICIPATED PROFITS OR BENEFITS PURCHASER S SOLE AND EXCLUSIVE REMEDY IS AS SET FORTH IN THE LIM...

Страница 24: ...before installation occurs Copyright 2000 by The GSI Group Printed in the USA For more information contact the DMC Distribution Center closest to you Clear Lake Distribution Center 5205 4th Ave South...

Отзывы: