TROUBLE SHOOTING GUIDE (continued)
PROBLEM
PROBABLE CAUSE
SOLUTION
Red LED indicator
1.
Wiring error
1.
Check the 5
does not come on
wire connections
at moisture limit
on the terminal
setting
for the digital
panel meter
“AVG ON” LED
1.
Averaging switch
1.
Check wiring
does not work
wired incorrectly
2.
Averaging switch not
2.
Relocate switch
in flow of grain
3.
Averaging switch bad
3.
Replace switch
“AVG ON” LED
1.
Object jammed on
1.
Remove object
stays on when
averaging switch
out of grain
Blowing the control
1.
DC power wires are
1.
The red wire
fuse (2 Amp AGC)
crossed
must be hooked
to positive 12 volts.
White is hooked to
ground.
2.
Sensor wires damaged
2.
Replace the
and shorted to ground
sensor and cable.
3.
Control board failure
3.
Replace the control
board
1.
Never unplug or plug in the circuit board with power on.
2.
Do not make field adjustments on the circuit board. This is a factory adjustment only.
3.
On combines where the sensor is mounted in a horizontal tube, the sensor should
be removed from the auger tube and the grain cleaned out before storing the
combine between seasons.
4.
Contact your dealer or DMC if you have any questions on the operation or service
of your combine Calc-U-Dri Moisture Monitor.
TAKE TIME FOR PROPER INSTALLATION --- IT SAVES SERVICE CALLS!