Operation
58
User’s Manual V1.00
DLoG MTC 6
8.3.
Operating states
The following operating states are possible for the DLoG MTC 6:
Status of internal LEDs
Power (green)
Temp (red)
DLoG MTC 6 status
OFF OFF
Initial state, idle time - waiting for a new ignition
signal after switch-off; no power supply
OFF FLASHING
Temperature sensor malfunctioning
FLASHING
OFF
DLoG MTC 6 is in stand by mode (S3).
OFF ON
The computer will not start until the temperature
inside the unit is between -30 °C and +62 °C
again.
ON OFF
Computer is starting up; normal operational
state; shutdown delay time is running
ON
ON
Temp. < -30 °C or Temp. > 70 °C
ON
FLASHING
Temperature sensor malfunctioning;
automatic switch-off software configuration