Mounting
DLoG MTC 6
User’s Manual V1.00
47
7.4.
Power supply
The DLoG MTC 6 is equipped with a galvanically separated, integrated DC power
supply.
Power is connected to the underside of the unit using a Phoenix Contact plug. There is
no power switch.
Caution:
Property
damage
The DLoG MTC 6 must only be connected to a SELV circuit.
*)
Ensure that there is a suitable disconnecting device such as a
power switch or circuit breaker in the power supply circuit. Ensure
that the disconnecting device isolates all supply voltage lines
.
The DC+ connecting cable must be protected by a fuse
(30 AT max.).
The ignition connecting cable must be protected by a fuse of the
following type: 5x20 mm T 125 mA L / 250 V, for example, a
Wickmann 195-125 mA / 250 V.
*) The SELV circuit is a secondary circuit that is designed and protected so that its voltages will
not exceed a safe value both when operating correctly or if a single error occurs.
WARNING
Use the connecting cables supplied by DLoG to connect the DLoG
MTC 6 to the power supply.
Make sure that the connecting cables are laid without kinks and are
protected.