Device
description
DLoG ITC 7
User’s Manual
17
3.5.8.
AC power pack
The DLoG ITC 7 has an external AC power supply with the following technical data:
•
100 - 240 VAC
•
1,5 A
•
50 up to 60 Hz
•
Maximum output 66 W
WARNING
DLoG ITC 7 devices with AC power pack should only be
connected to TN and TT networks. IT networks are not permitted
as dangerous electric shocks cannot be ruled out here.
Caution:
Property
damage
The DLoG ITC 7 may only be operated with the AC power supply
provided by DLoG!
Operating the DLoG ITC 7 without the AC power supply provided
can irreparably damage the DLoG ITC 7.
3.5.9.
Maximum power available for peripheral devices
The following maximum power may be drawn from the external interfaces of the
DLoG ITC 7:
•
USB: 2.5 W per interface
•
COM1 and PS/2: a total of 5 W
•
In all, the total power drawn may not exceed 10 W.
3.5.10.
Power supply fuses
The DLoG ITC 7 is equipped with a reversible fuse which resets itself after a short circuit
once the electrical current is no longer flowing through it. It can thus be used more than
once.