Operation
46
User’s Manual
DLoG ITC 7
8.2.4.1.
LED states, operating states
The following temperature information refers to the temperature in the device, not to the
ambient temperature.
Status of internal LEDs
Power (green)
Temp (red)
DLoG ITC 7-status
OFF OFF
Initial state, idle time; no power supply.
AUS FLASHING
Temperature sensor malfunctioning
OFF ON
The DLoG ITC 7 is switched off and the
temperature in the device is outside of the
allowable range.
Low-temperature warning
:
occurs at temperatures of < 0 °C
High-temperature warning:
occurs at temperatures of > +70 °C
The DLoG ITC 7 only starts when the
temperature in the device is again within the
range of 0 °C to +70 °C.
ON OFF
The DLoG ITC 7 is either being started or is in
normal operation.
ON ON
The DLoG ITC 7 is running and the temperature
in the device is < 0 °C or > +70 °C.
After about three minutes, the DLoG ITC 7
switches off.
ON FLASHING
The temperature sensor is defective.
Or:
DLoG ITC 7 is currently being configured, e.g.
using the “DLoG Config Tool”.