9024-065-G-11-14
26
4.2 DIP-Switch Settings for 4100 Circuit Board
Switch
Function
Setting
Description
SW 1 (Top 8 Switches)
Operator
Opening
Direction
OFF
ON
OFF
ON
OFF
ON
OFF
ON
6-OFF
6-OFF
6-ON
6-ON
7-OFF
7-ON
7-OFF
7-ON
Auto-Close
Timer
Maglock
Relay
Terminal 13-14
1
2
3
4
5
8
6 and 7
The output wired to main terminal 4 becomes the output from the exit loop detector
plugged into the EXIT Loop port.
Normal Setting.
Main terminal 4 is a normal full open input.
Auto-close timer is OFF. Manual input required to close gate.
Normal Setting.
Auto-close timer is ON. Adjustable from 1-23 seconds.
Maglock is
NOT
used. Solar Power setting.
Maglock is used and connected to main terminals 11 and 12.
OFF
ON
Normal Setting.
Quick close feature is OFF.
Quick close feature is ON. Opening gate will stop and begin to close as soon as
all reversing inputs (Reverse loops, photo sensors) are cleared regardless of the
distance the gate has opened.
OFF
ON
Normal Setting.
Main terminal 10 is a REVERSE input.
Main terminal 10 is a SHADOW loop and is
NOT
used on the 9024.
Normal Setting.
Relay activates when gate is at open limit.
Relay activates when gate is not closed.
Relay activates when gate is opening and open.
Relay activates during opening and closing cycle.
1-OFF
1-OFF
1-ON
1-ON
2-OFF
2-ON
2-OFF
2-ON
Select
Operator
Type
1 and 2
Slide Gate Operator
Swing Gate Operator
Barrier Gate Operator
Overhead Gate Operator
Switch
Function
Setting
Description
SW 2 (Bottom 8 Switches)
Switches 7 and 8
MUST
be turned
OFF
for Model 9024 operator.
OFF
ON
OFF
AC Power
Failure Mode
Reverse/Shadow
Input
Overlapping
Dual Gates
3
4
7 and 8
Gate operator will continue to operate normally using ONLY battery power.
Gate operator will fully open gate and shut down until AC power is restored.
OFF
ON
Input Power
Type
6
Input power is 115/230 VAC.
Input power is Solar.
OFF
ON
5
Single gate setting or overlapping gates are
NOT
used. Gates open at same time.
Overlapping gates
ARE
used (Dual gates ONLY). Secondary gate starts to open a
few seconds before primary gate starts.
Opening direction
using
ON
setting.
Opening direction
using
OFF
setting.
Changes direction operator will cycle open
upon initial AC power up and open command.
Reverses Gate
Stops Gate
Quick-Close
Timer Override
Exit Loop Port
Output
Full Open Input
Normal Setting.
Input to main terminal 10 and reverse loop will
reverse
gate
during
close
cycle.
Input to main terminal 10 and/or reverse loop will
stop
gate during
close
cycle –
gate will continue to close after input to main terminal 10 and/or reverse loop are
cleared (Helps prevent tailgating).
The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on
or off various operating features. Whenever a switch setting is changed, reset button must be pressed for the new setting to
take affect.