4.1 4100 Circuit Board Descriptions and Adjustments
SECTION 4 - ADJUSTMENTS
The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete.
Whenever any of the programming DIP-switches on the circuit board are changed, ALL power must be shut-off,
and then turned back on OR press reset button for the new setting to take effect.
Self-test mode is for bench
checks ONLY! Operator
MUST
be disconnected from the gate.
The operator will continually
cycle the gate.
The jumper must be set
at normal mode for
normal operater function.
Self-Test
Mode
Normal
Mode
Single Channel Plug-In Loop Detectors
(Sold separately)
Limit/
Alarm
Plug P3
Terminal
10-Pin UL 325/
3 Button Station
Removable Terminal
See pages 30-32.
3 Button
Station
Jumper
See page 35.
20-Pin
Main Terminal
See pages 34 and 35.
Battery Plug P2 Terminal
EXIT Loop T
erminal
REVERSE Loop T
erminal
Self-Test
Adjust reversing sensitivity for
the open
AND
close direction
of the operator, See page 29.
Inherent
Reverse Sensor
Loop LEDs
Input LEDs
See page 34.
Tracker
Data
See page 33.
Input LEDs
should be OFF and will only illuminate when the input that
is next to the LED is activated. See page 34.
Limit LEDs
will only illuminate when the respective limit switch has
been activated.
Loop LEDs
will only illuminate when a reverse or exit loop is activated
(Vehicle passing over a loop).
Limit LEDs
3 Button LEDs
Battery Charging
LED Monitor
See pages 22, 24
Power Select Jumper
Solar Power: Page 22
AC Power: Page 24
OPEN
CLOSE
STOP
Illuminated
LEDs
Indicates that low voltage power is being
applied to the circuit board.
How LEDs Function
Auto-close timer
(when turned on)
SW 1, switch 2.
Time Delay:
Adjust from 1 second
(full counter-clockwise)
to approximately 23
seconds (full clockwise).
Auto-Close Timer
ON
1
2
345678
SW 1
DIP-Switches
ON
1
2
345678
SW 1
ON
1
2
345678
SW 2
Set the DIP-switches
on the circuit board
to the desired
setting. See
switch-settings on
next 2 pages.
REV SENSE
Max
Min
LED
Reset Button:
Press
after changing a setting on
the board or if board locks
up during operation.
Board Relay
Dry relay contacts
(terminals 13-14) can
be set for Normally
Open (NO) or Normally
Closed (NC) operation
by placing the relay shorting bar on the N.O.
or N.C. pins respectively. SW 1, switches 6
and 7 must be set to control relay. See next
page for descriptions.
NC
NO
Key Switch:
Cycles the
operator when pressed.
Will use Auto-Close timer
when turned ON.
Note:
If powering up operator
using
ONLY DC power
, the key
switch
MUST
be pressed
AFTER
DC power switch is turned ON to
power up operator.