Note: If after the controller is switched on, the display is not lit up, check
whether there is voltage in the mains socket, then check the fuses and
replace if damaged with new ones 2 x 5 A. If, after the replacement of
fuses the display remains dark, please contact the maintenance provider.
!
Note: Always replace fuses with the unit switched off and the plug
removed from the socket.
!
Connection of the controller to the electrical system
1.
Connect the fan, pump and feeder with the appropriate power cables (see -
Figure 3).
2.
Install all necessary sensors (and reed relay for the piston feeder) acc. to Fig.4
and Fig.6.
3.
Put the plug of the controller power supply cable in a ~ 230 V socket.
4.
Switch the controller on, using the power switch.
Fan, feeder and pumps wiring diagrams
5
5
M
N
L
blue wire N
brown wire L
yellow-green wire
M
Fig.5 Power supply cable wiring diagrams for the fan, feeder, pump, etc. (Depending on the version of the
controller).
Содержание Master 500