Emergency stop of the piston feeder
The parameter defines the time (in seconds) ensuring a full cycle of the feeder
drawer. If, for some reasons, it is jammed, then, after that time the feeder and the fan
will be stopped in emergency mode, and the screen will indicate a feeder fault - see
more
Alarms - piston feeder drawer fault
.
: from 10 s to 200 s.
Change range
Pressing again takes you to the next setting.
This parameter allows you to set the maximum operating power of the fan.
range: from 40 % to 100 %.
Change
Adjusting the maximum fan power
Pressing again takes you to the next setting.
This parameter allows you to set the fan operating time during damping, i.e. after the
temperature drop at the boiler by the "dt" parameter. Change range: from 0 min to 45
min.
Adjustment of damping time
Pressing again takes you to the next setting.