Measured temperature range
from - 9 °C to + 120 °C
Boiler temperature setting range
from + 45
°
C to + 80
°
C
Hot water heater temperature range
from + 40 °C to + 70 °C
Temperature setting range for the CH pump
from + 30 °C to + 70 °C
Smooth start of the fan
yes
Adjustable maximum fan power
40 - 100 %
Fan hysteresis (difference between ON - OFF)
from 1 °C to 9 °C
DHW pump hysteresis (difference between ON - OFF)
from 2 °C to 9 °C
Blowing control (option to completely
operation: 0 - 90 seconds
disable blowing)
break: 1 - 60 minutes
Adjustable boiler damping time
0 - 45 minutes
Allowable load on outputs
fan: 100 VA (W) / 230 V
feeder: 200 VA (W) / 230 V
CH pump: 100 VA (W) / 230 V
DHW pump: 100 VA (W) / 230 V
Rated supply voltage
~ 230 V, 50 Hz
Electrical protection
2 x 5 A
Air relative humidity
<
95 %
Enclosure protection grade
IP 20
Ambient temperature
from 0 °C to + 40 °C
Software class
A
Operation type
fan: 1Y
feeder: 1B
CH pump: 1B
DHW pump: 1B
Specifications
31
34
Note: Depending on the software version, some setting ranges may differ from the above