Under the DMX control mode, slide down channel 1 to OFF (value 0-10), then back to ON (value 11-255), to let the machine run again.
The warning will disappear until the fluid is pumped and fill the tube.
•
Turn off “Fluid Sensor” in the menu.
6
TECHNICAL INFORMATION
6.1
Maintenance
1、
Please use DJPOWER PRO Neutral Fluid only.
2、
Any reference to servicing in this User Manual will only apply to properly trained, certified technicians. Do not open the housing or
attempt any repairs which can lead to damage or malfunction.
3、
Excessive dust, fluid residue and dirt will degrade performance and cause overheating. Remove dust from air vents with air
compressor, vacuum or soft brush. The casing could be cleaned by the damp cloth.
Test-run your DJPOWER® CAT-2 on a monthly basis to achieve the best performance.
6.2
Storage
6.2.1
Machine Storage
Before storing the machine, clean it and empty the fluid tank.
6.3
Troubleshooting
Errors
Symptom
Potential Cause
Solution
No fluid
Refer to “MENU MAP” chapter to for more
information
No fluid in the tank
Refill the fluid
Pump problem
Contact dealer for Service
Heating failure
Refer to “MENU MAP” chapter to for more
information
Heater problem
Contact dealer for Service
Low pressure
Refer to “INSTALLATION” chapter to for more
information
Low pressure
Check the gas cylinder: if the hose is in
correct connection; if there is enough
gas in the cylinder