background image

Do not use in a confined space. Always install the product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent 
surfaces. 

Be sure that no ventilation slots on the product’s housing are blocked.

1.5.3

 

Power and Wiring 

Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear 
panel of the product. 

Make sure the power cord is not crimped or damaged.

Do not connect the machine to the dimming controller or rheostat.

Never disconnect the product from power cord by pulling or tugging on the cord.

To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via 
breaker or by unplugging it. 

1.5.4

 

Operation 

Do not operate this product if you see damage to the housing or cables. Have the damaged parts replaced by an authorized technician 
at once. 

Make sure there are no flammable materials close to this product while it is operating.

Do not cover or plug the output nozzle during operation.

Do not cover the vents always.

Do not use the product as a space heater.

Never carry the product by the power cord or any moving part. Always use the handles.

Empty the storage bin before transporting the product.

The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate the product at higher temperatures.

Always disconnect the product from the power source before cleaning.

This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained,
certified technicians. Do not open the housing or attempt any repairs which can lead to damage or malfunction.

In the event of a serious operating problem, stop using the product immediately.

Use only DJPOWER Professional Neutral Fluid PRO-GX and CO2 or N2.

2

 

INTRODUCTION 

2.1

 

Description 

TOPCAT CAT-2 Atmospheric Generator creates fog or haze effect from a single device. It breaks through the traditional concept of fog or 
haze machine by mixing CO2/Nitrogen with oil based Pro Neutral Fluid, then uses evaporator to produce massive tiny particles, delicately 
enhancing the light effect. 

The particles are very small, about 0.5 microns. They can spread very quickly in the air even with little air flows.  

Fluid being used is made of a special environmentally friendly oil which can keep the haze stay in the air for longer time. 

The high quality fine haze effect makes it best mate for the professionals to create an amazing show.  

2.2

 

Features 

• Automatic troubleshooting function.

• Automatic cleaning function.

• Low fluid consumption.

• Dual fluid supply system.

• Independent fan control, three output directions.

Содержание TOPCAT CAT-2

Страница 1: ......

Страница 2: ...The information and specifications contained in this User Manual are subject to change without notice DJPOWER assumes no responsibility or liability for any errors or omissions and reserves the right to revise or to create this manual at any time Copyright 2019 DJPOWER All rights reserved 1 5 Safety Notes Please read the following Safety Notes carefully before working with the product The notes in...

Страница 3: ...n before transporting the product The maximum ambient temperature Ta is 104 F 40 C Do not operate the product at higher temperatures Always disconnect the product from the power source before cleaning This product contains no user serviceable parts Any reference to servicing in this User Manual will only apply to properly trained certified technicians Do not open the housing or attempt any repairs...

Страница 4: ... low noise and anti humid fan 110V 240V wide voltage Two fans to switch the haze output UP or DOWN Support RDM function Built in LCD control 3 pin and 5 pin DMX control 2 3 Product Overview 2 4 Product Dimensions ...

Страница 5: ...channel serves only as a 0 to 100 switch AC Power Input Voltage Rate AC 110V 240V 50 60Hz Current Limiter Type Breaker Current Limiter Specifications 8 A 250 V Nominal Total Power Consumption 715 W Heating Heat Up Time Appr 8 min Capacity Fluid Tank Capacity 3 L Output Fog Fan Adjustable Output Continuous Output Max Output Volume Appr 24 000 cfm Max Output Distance Appr 10 m Gas consumption Rate 1...

Страница 6: ...his product Before deciding on a location for the product make sure there is easy access to the product for maintenance and programming purposes Make sure that the structure or surface onto which you are mounting the product can support the product s weight see the Technical Specifications When mounting the product on the floor make sure that the product and cables are away from people and vehicle...

Страница 7: ...scription Parameter Range Starting Page TOPCAT CAT 2 Version 1 0 Preparing Page Heating up The machine is heating up Standby Page Ready to work TOPCAT Finished heating up ready to work The machine will heat up automatically when power on If the temperature of the heater is lower than the set temperature the LCD display will show Heating up if it reaches the set temperature it will show Ready to wo...

Страница 8: ...Forward mode Down mode Up mode Forward mode Pump Switch on The unit comes with two pumps In case this function ON the pump switches to another every time when the unit is powere d on Press or to select the status On off Status Pages Self Clean Initializing When the unit is out of DMX control for 15 seconds or if holding ENTER button for 3 seconds the unit will enter into Self Clean mode Press any ...

Страница 9: ...er the forward mode 2 Fog Output 0 10 No Function 11 255 1 100 increase 3 Work Mode 0 85 Down mode 86 171 Up mode 171 255 Forward mode 4 Forced pumping mode 0 5 Turn off reset the forced pumping mode 6 253 Hold no operation 254 255 Enable the forced pumping mode and it will be shut down after 10 seconds If you need to enable the forced pumping mode again please reset the forced pumping mode first ...

Страница 10: ... operating at standalone mode On device manual control the Auto Run Last Setting will allow the machine to recover its previous same operating status when the unit is powered on again without pressing any button Shut off Get disconnected from power supply or turn off the power switch Power on Get connected with power supply or turn on the power switch 5 7 Fluid Sensor This machine uses software ba...

Страница 11: ... overheating Remove dust from air vents with air compressor vacuum or soft brush The casing could be cleaned by the damp cloth Test run your DJPOWER CAT 2 on a monthly basis to achieve the best performance 6 2 Storage 6 2 1 Machine Storage Before storing the machine clean it and empty the fluid tank 6 3 Troubleshooting Errors Symptom Potential Cause Solution No fluid Refer to MENU MAP chapter to f...

Страница 12: ......

Отзывы: