• Suitable places for installation of this device are shown in Figure
1.2.1 and 1.2.2.
• Combi boilers are not allowed to be connected on oven, in places where
acid vapor or potentially explosive materials are present, in bathroom,
over chimney wall, in bright places or places connected to bright
balconies.
• In open balconies, chimney pipe is to be outwards and environmental
winds should not exceed 10 m/s.
• In the case that device is placed inside a cabinet, minimum distance
from sides, top and bottom should be 100 mm, 100 mm and 200 mm
respectively so that it can be serviced.
Minimum lengths related to placement of chimney outlet (in cm)
A- Under a window..........................................................................................60
B- Under an air vent........................................................................................60
C- Under rain channel.....................................................................................30
D- Under balcony............................................................................................ 30
E- Next to a window.........................................................................................40
F- Next to an air vent.......................................................................................60
G- Next to a vertical or horizontal pipe............................................................60
H- Under distance vent from building’s outer corner....................................…30
I- Distance from building’s outer corner........................................................100
J- From floor or coating.................................................................................180
K- Vertical distance for two chimney outlets.................................................150
L- Horizontal distance for two chimney outlets.............................................100