17
Rotary Lobe Pumps - RZL-400 Series
800.789.1718
Tools Needed
•
Rotor tool
•
Plastic dowel
•
Open ended wrench set
•
Rubber mallet
•
Flat head screw driver
•
Feeler gauges
•
Hex keys
•
O-ring pick
•
Spanner wrench
•
Rotor extraction tool (optional)
Additional tools needed when assembling or disassembling gear box
•
Spanner wrench
•
Arbor press or bearing puller
Maintenance
Pump Housing Disassembly - Single Mechanical Seal
Prior to removal of pump, the shut-off valves in the suction and discharge lines must be closed. If there is any risk that product
may harden, crystallize or freeze in the pump it should be thoroughly drained and cleaned immediately after use. Same
attention applies if there is a seal flush option. Power needs to be locked out to prevent unintended start of the pump.
Note: Reference numbers are listed in the sectional view located on pages 61-73.
1.
Loosen and remove the four hex nuts (33) from the front cover.