16
Rotary Lobe Pumps - RZL-400 Series
800.789.1718
Installation & Start Up
At Start Up
Pump Alignment:
•
A flexible coupling is used to compensate for end play and small differences in alignment. The pump and drive shaft should be
aligned as closely as possible.
•
Check angular alignment using feeler or taper gauge.
•
Adjust to get equal dimension at all points – at the same time, set space between coupling halves to the coupling manufacturer’s
recommended distance.
•
Note: Pump is aligned prior to shipping, after installation verify alignment as misalignment may have occurred during shipment.