category window) to the devices connected to the RS 485.
To change the category click inside the field and select the appropriate item.
Click “Confirm” now or at the end of the whole configuration.
3.3.4.4
ASSIGN THE ALARM TYPOLOGY
Be sure of having selected the right instrument i
n the “Selection” field.
ALARM ORIGIN:
depending on the instrument model there are different available alarms, if you do not
find the right one it means that it is not available for that instrument.
LABEL:
each alarm can be assigned with an appropriate label defined by the user, this label is also used
when it is displayed by the system.
ALARM TIPOLOGY:
links alarm type to the proper Alarm typology.
If you do not find the proper action in it, step back to the Alarms definition to insert the new features into a
new alarm typology.
THIS FOR ALL DEVICES:
by clicking this button you can set all the instrument with the new alarm values.
The alarm configuration obtained is repeated for all the instruments having these compatible fields.
SND
(Send): when enabled the alarm is treated also to be sent.
REC
(Recording): when enabled the corresponding alarm is logged.
Click “Confirm” now or at the end of the whole configuration.
3.3.4.5
DEFINE THE DIGITAL, ANALOGUE INPUTS AND THE STATUS
The lower area is dedicated to the analogue inputs (probe), digital inputs, digital outputs and status
assignments.
NAME:
The first time each name is displayed by following the internal XWEB archive of standard feature
of the instruments. Each definition can be renamed when necessary to give the proper meaning. Beware
of the difference between integer and decimal value. Instruments are factory preset to decimal point, so if
you change this value to integer you need to make the same change inside XWEB. All default labels are
intended as decima
l, when you change to integer a postfix “-I” is shown. It may happen that you move to
integer using advanced properties (see Appendix A), then coming back to label name and changing it
without using “-I” you completely loose the information you are displaying integer. This may be a problem
because when you come back to advanced section there is no more difference between decimal and
integer.
Udm:
The analogue input is followed by the proper unit of measurement, change the unit by clicking in it
then insert the new value. Beware that in this window you can change only the label of the unit of
measurement. In Advanced section you can change the behaviour of the instrument (e.g. Celsius or
Fahrenheit degree)
Read:
when enabled the value is computed and displayed.
Save:
when enabled the value is logged.
Click “Confirm” now or at the end of the whole configuration.
Delete one device from the list
From Selection find the instrument to delete.