![Diwel Melody caster Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/diwel/melody-caster/melody-caster_user-manual_2510960007.webp)
The equipment can have a user configurable transmission power, from 6 dBm up to 25 dBm.
This allow to use different type of antenna and cable, and compensate the power loss in these cable.
The conformity test have been performed with a 7 dBi gain antenna and the maximum power output
To comply with the regulation, when using the channel 1 to 8 (5180 MHz to 5320 MHz), the
equivalent isotropically radiated power (
EIRP
) must be lower than 200 mW (23 dBm). If the
equipment is set to 25 dBm power, a cable of at least 7 dB attenuation must be used if a 7 dBi
antenna is used.
When using the channel 20 to 24 (5745 MHz to 5825 MHz), the EIRP must be lower than 25 mW
(14 dBm), a cable of at least 6 dB attenuation must be used if a 7 dBi antenna is used.
When using a different antenna, or different cable, the maximum allowed power may be achieved
by lowering the power generated by the product (using the front panel, or from the web interface).
It is the installer’s responsibility to follow local country regulations including operation within
legal frequency channels. The End User is responsible for keeping the unit working according
to these rules.
7/28