33
Pumps
PROBLEM
PROBABLE CAUSE
REMEDY
Noisy pump or motor A) Clogged filter or pump
inlets.
Clean filter, filter basket and
pump inlets
B) Low water level.
Fill water to fill line on filter
door.
C) Slice valves not open.
Remove service panels and
open slice valves.
D) Debris in pump(s).
Contact customer service.
E) Damaged or worn
motor bearings.
Contact customer service.
Motor not functioning A) Cord unplugged or
damaged.
Check wiring to controller.
Contact customer service.
B) Motor overloaded.
Let motor cool for one hour,
open all jets. Motor will reset
automatically.
C) Defective start switch.
Contact customer service.
D) Blockage in line.
Contact customer service.
E) Kink in hose.
Remove service panels and
check for a kinked hose.
F) Slice valves not open.
Remove service panels and
open slice valves.
G) Blown fuse.
Check fuses. Replace if bad.
Jets
PROBLEM
PROBABLE CAUSE
REMEDY
Rotating jets won’t
rotate
Debris in jet housing.
See ‘Cleaning the rotating jets’
section of the JETS chapter.
Water
PROBLEM
PROBABLE CAUSE
REMEDY
Water leak
A) Compression fittings
(unions) have loosened.
Tighten fittings.
B) Leak at barbed fitting.
Cut off hose clamp through the
raised ear portion and reseat
hose. Reconnect with a new
hose clamp or a ‘worm drive
clamp’.
Содержание DL-1040 DLX
Страница 18: ...18 energy efficient spas engineered with technology SAVE ENERGY SAVE MONEY SAVE OUR PLANET ...
Страница 38: ...38 NOTES ...
Страница 39: ...39 NOTES ...