•  Read and understand 

SECTION 1:  Safety Precautions

 and 

SECTION 4:  Operation

 before use

•  Read and understand all Material Safety Data Sheets and Manufacturer’s instructions of all  
    process materials, consumables, and equipment used in conjunction with this equipment.
•  Keep away from all mechanical moving parts including motor, gears, and other pinch points.
•  Do not use product without first confirming if a Spark Arrestor is required and installed for 
    the type of dust, or fumes you are extracting and/or collection.  If you are unsure, call a 
    Diversitech representative at 1-800-361-3733.

 

4.1 Operate Safely

4.2 Controls

9

SECTION 4 - OPERATION

Fuses

PLC LCD 

Display/mes

sage center

Start

Stop

Alarm 

Annunciator

Contacter

Overload

Aux Fan Current

monitoring

Pic

DC Power

Supply

Содержание TYPHOON WX Series

Страница 1: ...t www diversitech ca 1200 55th Avenue Montreal Quebec H8T 3J8 Tel 1 800 361 3733 Fax 1 514 631 9480 info diversitech ca READ AND SAVE THESE INSTRUCTIONS WX 1200 WX 5000 WX 3000 WX 6500 Operation Maint...

Страница 2: ...ERATION 9 4 1 To Operate Safely 9 4 2 Controls 9 4 3 Principles of Operation 10 Control System Explained 10 Water Level Monotoring 10 Alarms 11 Level Set Point 11 SECTION 5 MAINTENANCE TROUBLESHOOTING...

Страница 3: ...that extracts fumes collects dusts and exhausts filtered air either indoors or outdoors Before use inspect the unit for damage and verify it is working properly Only qualified persons should install o...

Страница 4: ...o 3000 5000 80 10 0 3P 60Hz 28 0 14 0 11 0 78 WX 6500 auto 4000 6500 80 15 0 3P 60Hz 34 0 16 9 14 0 80 1 For 1200 Airflow 2 external static pressure 2 For WX 3000 WX 5000 WX 6500 Airflow 2 5 external...

Страница 5: ...PT WX 5000 16 61 117 57 1 2 NPT 1 NPT WX 6500 16 67 129 67 1 2 NPT 1 NPT 1 Water Level is marked on each unit Collector Model Table Model Optimal Connection a Footprint Water Water Level in Length b H...

Страница 6: ...rting during handling 4 The item serial number model and electrical ratings are listed on the nameplate Record this information in the Maintenance Record provided in APPENDIX 2 Maintenance Record or y...

Страница 7: ...cabinet Once reinstalled the electrical connection to the main control box must be made as per the provided wiring diagram The scrubber is designed to accommodate an auxiliary vent fan that operates w...

Страница 8: ...to use in your application turn the unit ON and perform a function test To do so 1 Turn switch to ON position for a few seconds to check that the motor rotation is correct by looking down the back of...

Страница 9: ...chanical moving parts including motor gears and other pinch points Do not use product without first confirming if a Spark Arrestor is required and installed for the type of dust or fumes you are extra...

Страница 10: ...h HEPA option 6 Interface for auxiliary vent fan 7 Current sensing alarm for auxiliary vent fan 8 Master Slave input for scrubber to run when dust producing equipment is on may require additional hard...

Страница 11: ...m will remain until the situation is corrected Level Set Point Initial Set Point Adjustment if the PLC has been factory reset At the initial star up the set point will be at 0 To set the running water...

Страница 12: ...this product Disconnect power before performing any maintenance on unit including filter inspection The input power to this unit is high voltage and touching any live electrical parts can cause fatal...

Страница 13: ...Inspect the mist eliminator filters inside the unit for holes or dust accumulation replace the media if torn or dirty All debris must be stored in a ventilated metal drum to prevent hydrogen gas buil...

Страница 14: ...vel Check input water and probes Fill to indicated level if necessary CORRECT Air Flow Restricted Air Flow Restricted Check clean pre filters and ducts between table and scrubber Check clean scrubber...

Страница 15: ...ance on unit including filter inspection The input power to this unit is high voltage and touching any live electrical parts can cause fatal shocks or severe burns Do not touch live electrical parts A...

Страница 16: ...the bicolor LED D rapidly flashes green 5 Releases the button The bicolor LED continues to flash green 6 Within 30s insert an object into position 1 then push and release the setup button The bicolor...

Страница 17: ...m will be activated HEPA Installation HEPA installations follow NFPA guidelines thus temperature sensors are installed on the exhaust side of the HEPA filter These sensors are set at approximately 450...

Страница 18: ...pied or otherwise reproduced as needed for management of maintenance records MANUFACTURER DIVERSITECH INC MODEL N WET COLLECTOR SERIAL N SERVICE LOCATION CONTROL N Date Description of Service Serviced...

Страница 19: ...19 NOTES...