• Instructions to install 15HP Blower (Lift truck required to hoist motor)
3.5 Preparing Unit for Operation
1. Unbolt and remove square panel, unbolt and remove blower plate.
2. Inside the blower housing, fasten 2 bolts attaching the scroll to the wet collector.
3. Using the hardware, fasten the cone to the scroll while aligning the cone in the center of the Blower Wheel.
Cone
Blower wheel
4. Wire the motor to electrical panel using the existing wiring.
8
• Before plugging unit in to an input power source, look at the manufacturer’s label located on the exterior of
the unit and ensure the source is correctly sized in terms of Voltage and Amperes.
• Prior to use in your application, turn the unit ON, and perform a function test. To do so:
1. Turn switch to ON position for a few seconds to check that the motor rotation is correct by looking down
the back of the motor and checking that the motor fan turns in the direction of the arrow. Optionally a
current measurement can be done to ensure that the motor is not drawing excessive current (a sign of
reverse rotation)
2. LISTEN: Does the motor and suction sound smooth and within expected volumes.
3. FEEL: Place your hand on top of the unit and sense for unexpected vibration. Place your hand in front of
the intake hood/surface and sense for expected level(s) of suction.
• Inform all potential users of this equipment where they may find and review this manual.
Make sure the
rotation matches
the rotation
stickers
Blower
Housing
Blower Plate
Square
Panel
Bolts
Содержание TYPHOON WX Series
Страница 19: ...19 NOTES...