 JR-C / JR20-C

 

KOSMOS SERIE

 

www.ditel.es 

 
 

 
All information contained in this manual, unless indicated, is valid for both 

JR-C

 and 

JR20-C

 models. 

 

JR-C 

and 

JR20-C 

models  from  KOSMOS  serie  are  digital  indicators  fully  configurables  that  allow  input  type 

selection in order to be used as needed. Available signal inputs are the following: 

 

LOAD CELL 

(30mV, 300mV) 

 
The basic instrument  consists of a soldered  assembly composed  of a main board, a display and an input  signal 

circuits. It can also be incorporated, as an option, an extra plug-in 2 SPDT 8A relays circuit output which is isolated 
from signal input and power supply. This extra circuit has independent connectors that are located on the rear part 
of the instrument once it is installed. 

 
Specially designed for direct connection to Load cells, both models have 4 digits, configurable decimal point and 2 

LED’s for setpoints status indication, they are easy to scale into desired engineering units, directly by frontal keys 
or rear input signal value in teach mode. They also provide a 24V DC output for sensor excitation. 
 

JR-C 

model is provided with 

14mm-high 

digits and maximum display range of -

9999

 to 

9999

 whereas 

JR20-C 

has 

20mm-high 

digits and a maximum range of -

1999

 to 

9999

JR20-C 

has a larger display to provide a better 

reading at longer distance, although minus LED sign is integrated in the most significative digit instead of being 
external, as in 

JR-C 

model. 

 
Both devices have three frontal keys to interact with internal software and set configuration in order to adapt their 
function  to  particular  applications.  Device  programming  runs  through  some  independent  menus  that  show  short 

messages to easily identify input type and/or display configuration steps. 
 

If  relays  output  option  card  is  installed,  once  it  is  recognised  by  the  instrument,  activates  its  own  configuration 
menu which is only visible under this conditions. 

Device description 

Dimensions and mounting 

To  install  the  instrument,  prepare  a 
92x45mm  panel  cut-out  and  slide  the  unit 

inwards making sure of placing the sealing 
gasket  between  the  front  side  panel  and 

the frontal bezel. 
 
While  holding  the  unit  in  place,  put  the 

fixing  clips  on  both  sides  of  the  case  and 
slide  them  through  the  guide  tracks  until 

they reach the panel at the rear side. 

Press slightly to fasten the clips to the latching slots 
on  the  case  and  get  the  unit  fully  assembled  and 

close fitted to achieve a good sealing. 

To remove the instrument from the panel, pull outwards the rear fixing 
clips latching tabs until they are disengaged, then slide fixing clips back 

over the case. 

Содержание JUNIOR JR-C

Страница 1: ...JR C JR20 C KOSMOS SERIE www ditel es USER MANUAL DIGITAL INDICATOR FOR LOAD CELL INPUT JUNIOR JR C JR20 C...

Страница 2: ...tput 9 INPUT CONFIGURATION Configuration menu 10 Input configuration 11 DISPLAY CONFIGURATION Display programming 12 Display scaling 12 mV input 13 SETPOINTS CONFIGURATION Setpoints configuration 14 A...

Страница 3: ...rder to protect the environment and in agreement with the European legislation regarding waste of electrical and electronic equipments from products put on the market after 13 August 2005 the user can...

Страница 4: ...s benefit from an unlimited and inconditional warranty of three 3 years from the date of their purchase Now you can extend this period up to five 5 years from the product commissioning only by fulfill...

Страница 5: ...12 cycles Criterion C 70 V during 25 30 cycles Criterion C Short interruptions 0 V during 250 300 ciclos Criterion C CISPR11 Emission limits Class B EN 61010 1 Safety requirements for electrical equi...

Страница 6: ...s and a maximum range of 1999 to 9999 JR20 C has a larger display to provide a better reading at longer distance although minus LED sign is integrated in the most significative digit instead of being...

Страница 7: ...hen configuration menu is entered to programm the indicator whereas RUN is the normal mode in which display shows the reading according to configuration and input signal value The table below summariz...

Страница 8: ...minals Once all connections are done plug connectors to the instrument Rear connectors location Key tool for cable insertion Notes NO Normally open contact CM Common contact NC Normally closed contact...

Страница 9: ...between pin 4 and pin 5 of CN2 input connector must be able to provide a current of 4mA and withstand up to 40V In both cases remote TARE is activated when contact is closed less than 3 seconds Remot...

Страница 10: ...guration menu The instrument provides 3 keys for progressing through the menus and submenus and for data introducing modifying ENTER Vertical displacement Validates data UP Increases active digit valu...

Страница 11: ...E www ditel es 11 EXCITATION LEVEL Configurable value E 5 5V DC E 10 10V DC Once input range is selected the routine goes to configure excitation 5V and 10V are available In both cases load current li...

Страница 12: ...9 for JR C 14mm high digits or between 1999 and 9999 for JR20 C 20mm high digits Display scaling is a linear process that consists in introducing two input values referred as Input 1 and Input 2 and t...

Страница 13: ...P2 Display value indication 0000 Value entering in counts within available model display range FiLt 0 SCAL InP1 tEAC 0000 dSP1 0000 00 00 InP2 0000 dSP2 0000 For both display scaling SCAL and tEAC met...

Страница 14: ...from 0 to 99 9s HyS Hysteresis in counts within available model display range 00 00 SETPOINTS CONFIGURATION If 2RE output option card is uninstalled the instrument keeps setpoints last configuration i...

Страница 15: ...ated value does not exceed the limit value defined by the working range Otherwise overflow indication OuE will be displayed Stored tare value remains in memory although power supply is removed This de...

Страница 16: ...default this code is 0000 Finally press ENTER to begin with lock out level configuration If entered security code is wrong the instrument will go back to RUN mode 3s To access this menu from RUN mode...

Страница 17: ...out is available only when 2RE output is installed If 2RE output option card is uninstalled the instrument keeps setpoints last configuration in memory though it can not be visualized There will be no...

Страница 18: ...d SHIFT key lock out for MAX MIN function is configurable in the same way as previous configurations When lock out is enabled selecting yES it is not possible to visualize maximum or minimum values by...

Страница 19: ...te in each case just when setpoint SET is reached by display Hysteresis delay for OUT1 HI mode and for OUT2 LO mode 2RE output option allows JR P and JR20 P models to perform control operations and li...

Страница 20: ...its slide properly without much effort through rear case internal guides Each output card is supplied with an adhesive label that indicates wiring connections To help identifying terminals this label...

Страница 21: ...or contact switch MAX MIN and MAX MIN RESET func Through frontal key ENVIRONMENTAL CONDITIONS Operating temperature 10 C 60 C Storage temperature 25 C 85 C Relative humidity non condensing 95 40 C Max...

Страница 22: ...ing template for the annotation of configured parameters in your instrument for later consulting or data recover INPUT TYPE RANGE DISPLAY CONFIG MODE INPUT 1 DISPLAY 1 INPUT 2 DISPLAY 2 FILTER 0 8 SET...

Страница 23: ...JR20 C KOSMOS SERIE www ditel es 23 DISE OS Y TECNOLOG A S A Xarol 8 C P I Les Guixeres 08915 Badalona Spain Tel 34 933 394 758 Fax 34 934 903 145 Email dtl ditel es web www ditel es 02 04 2013 30727...

Отзывы: