SPECIFICATIONS 

Technical specifications 

 

 

 

  SPECIAL FUNCTIONS 

 

Return to factory configuration. 

 

Software configuration lock-out. 

 

 

 

  PRECISION 

 

Temperature coefficient  .......................................  100 ppm/ºC 

 

Warm-up time  .........................................................  5 minutes 

 

Specifications range  ................................................  23ºC±5ºC 

 

  POWER SUPPLY AND FUSES (DIN 41661) (not included)  

 

JR-C:

 

20-265 V AC 50/60 Hz and 11-265 V DC ..  F 3A/ 250V 

 

JR20-C:

  20-265 V AC 50/60 Hz and 11-265 V DC ..  F 3A/ 250V 

 

Power consumption (both models)  ......................................  3W 

 

Sensor excitation (both models) (stabilized)  ......... 5V or 10V DC 

 

Maximum load current  ...................................................  30mA 

 

  CONVERSION 

 

Technique  ............................................................ Sigma-Delta 

 

Resolution  .....................................................................  16 bit 

 

Conversion rate  ...............................................................  20/s 

 

 

  DISPLAY 

 

Range: 

 

JR-C  .....................................  -9999 ÷ 9999, 14mm RED LED 

 

JR20-C  .................................  -1999 ÷ 9999, 20mm RED LED 

 

Decimal point .......................................................  Configurable 

 

LEDs  .........................................  2 for setpoints state indication 

 

Display refresh rate ........................................................  50ms 

 

Display/input overrange indication  ...................  "

-OuE

"

 

, "

OuE

 

Sensor failure indication  ................................................  "

OuE

 

TARE and TARE RESET functions  ...............  Through frontal key 

 

Remote TARE function  .......  Logic input (O.C.) or contact switch 

 

Remote TARE RESET  .........  Logic input (O.C.) or contact switch 

 

MAX./MIN. and MAX./MIN. RESET func.  .....  Through frontal key 

 

  ENVIRONMENTAL CONDITIONS 

 

Operating temperature  .....................................  -10ºC ÷ +60ºC 

 

Storage temperature  ........................................  -25ºC ÷ +85ºC 

 

Relative humidity (non-condensing)  ...................  <95% @ 40ºC 

 

Maximum altitude  ........................................................  2000m 

 

Frontal protection degree  .................................................  IP65 

 

  INPUT SIGNAL 

 

Configuration  .....................................  Differential asymmetrical 

 

 

  mV DC input 

 

I

nput impedance  ............................................................  3M

 

 

EMI max. Influence (±30mV)  .........................................  ±6

V

 

 

EMI max. Influence (±300mV)  .....................................  ±60

 

Maximum input signal (±30mV)  ....................................  ±32mV 

 

Maximum input signal (±300mV)  ................................  ±320mV 

 

 
 

 
 

 

 
 

  FILTER 

 

Cutoff frequency (-3dB)  ................................  1.20Hz to 0.18Hz 

 

Slope  ....................................................................  -20dB/Dec. 

 

 

  DIMENSIONS 

 

Dimensions  ..................................  96 x 48 x 60 mm (1/8 DIN). 

 

Panel cutout  ........................................................  92 x 45 mm. 

 

Weight  ..........................................................................  150g. 

 

Case material  ...................................  UL 94 V-0 polycarbonate. 

 
 

  2RE OPTION 

 

Maximum switching current (resistive load)

 

 .........................  8A

 

 

Maximum sitching power  .................................  2000VA / 192W 

 

Maximum switching voltage  ..........................  400VAC / 125VDC 

 

Contact rating  .......................................  8A @ 250VAC / 24VDC  

 

Contact resistance  .............................  

 100m

 

at 6V DC @ 1A 

 

Contact type  ..................................................................  SPDT 

 

Operate time  ...............................................................  

 

10ms 

 

 

 

NOTE: 

In  case  that  the  outputs  are  used  to  drive  inductive 

loads, it is recommended to add an RC network between 
the  coil  terminals  (preferably)  or  between  the  relay 

contacts,  to  limit electromagnetic  effects  and to extend 
contacts life. 

RANGE 

RESOLUTION 

ACCURACY 

±30mV 

1

±(0.05%rdg + 6

V) 

±300mV 

15

±(0.05%rdg + 60

V) 

Содержание JUNIOR JR-C

Страница 1: ...JR C JR20 C KOSMOS SERIE www ditel es USER MANUAL DIGITAL INDICATOR FOR LOAD CELL INPUT JUNIOR JR C JR20 C...

Страница 2: ...tput 9 INPUT CONFIGURATION Configuration menu 10 Input configuration 11 DISPLAY CONFIGURATION Display programming 12 Display scaling 12 mV input 13 SETPOINTS CONFIGURATION Setpoints configuration 14 A...

Страница 3: ...rder to protect the environment and in agreement with the European legislation regarding waste of electrical and electronic equipments from products put on the market after 13 August 2005 the user can...

Страница 4: ...s benefit from an unlimited and inconditional warranty of three 3 years from the date of their purchase Now you can extend this period up to five 5 years from the product commissioning only by fulfill...

Страница 5: ...12 cycles Criterion C 70 V during 25 30 cycles Criterion C Short interruptions 0 V during 250 300 ciclos Criterion C CISPR11 Emission limits Class B EN 61010 1 Safety requirements for electrical equi...

Страница 6: ...s and a maximum range of 1999 to 9999 JR20 C has a larger display to provide a better reading at longer distance although minus LED sign is integrated in the most significative digit instead of being...

Страница 7: ...hen configuration menu is entered to programm the indicator whereas RUN is the normal mode in which display shows the reading according to configuration and input signal value The table below summariz...

Страница 8: ...minals Once all connections are done plug connectors to the instrument Rear connectors location Key tool for cable insertion Notes NO Normally open contact CM Common contact NC Normally closed contact...

Страница 9: ...between pin 4 and pin 5 of CN2 input connector must be able to provide a current of 4mA and withstand up to 40V In both cases remote TARE is activated when contact is closed less than 3 seconds Remot...

Страница 10: ...guration menu The instrument provides 3 keys for progressing through the menus and submenus and for data introducing modifying ENTER Vertical displacement Validates data UP Increases active digit valu...

Страница 11: ...E www ditel es 11 EXCITATION LEVEL Configurable value E 5 5V DC E 10 10V DC Once input range is selected the routine goes to configure excitation 5V and 10V are available In both cases load current li...

Страница 12: ...9 for JR C 14mm high digits or between 1999 and 9999 for JR20 C 20mm high digits Display scaling is a linear process that consists in introducing two input values referred as Input 1 and Input 2 and t...

Страница 13: ...P2 Display value indication 0000 Value entering in counts within available model display range FiLt 0 SCAL InP1 tEAC 0000 dSP1 0000 00 00 InP2 0000 dSP2 0000 For both display scaling SCAL and tEAC met...

Страница 14: ...from 0 to 99 9s HyS Hysteresis in counts within available model display range 00 00 SETPOINTS CONFIGURATION If 2RE output option card is uninstalled the instrument keeps setpoints last configuration i...

Страница 15: ...ated value does not exceed the limit value defined by the working range Otherwise overflow indication OuE will be displayed Stored tare value remains in memory although power supply is removed This de...

Страница 16: ...default this code is 0000 Finally press ENTER to begin with lock out level configuration If entered security code is wrong the instrument will go back to RUN mode 3s To access this menu from RUN mode...

Страница 17: ...out is available only when 2RE output is installed If 2RE output option card is uninstalled the instrument keeps setpoints last configuration in memory though it can not be visualized There will be no...

Страница 18: ...d SHIFT key lock out for MAX MIN function is configurable in the same way as previous configurations When lock out is enabled selecting yES it is not possible to visualize maximum or minimum values by...

Страница 19: ...te in each case just when setpoint SET is reached by display Hysteresis delay for OUT1 HI mode and for OUT2 LO mode 2RE output option allows JR P and JR20 P models to perform control operations and li...

Страница 20: ...its slide properly without much effort through rear case internal guides Each output card is supplied with an adhesive label that indicates wiring connections To help identifying terminals this label...

Страница 21: ...or contact switch MAX MIN and MAX MIN RESET func Through frontal key ENVIRONMENTAL CONDITIONS Operating temperature 10 C 60 C Storage temperature 25 C 85 C Relative humidity non condensing 95 40 C Max...

Страница 22: ...ing template for the annotation of configured parameters in your instrument for later consulting or data recover INPUT TYPE RANGE DISPLAY CONFIG MODE INPUT 1 DISPLAY 1 INPUT 2 DISPLAY 2 FILTER 0 8 SET...

Страница 23: ...JR20 C KOSMOS SERIE www ditel es 23 DISE OS Y TECNOLOG A S A Xarol 8 C P I Les Guixeres 08915 Badalona Spain Tel 34 933 394 758 Fax 34 934 903 145 Email dtl ditel es web www ditel es 02 04 2013 30727...

Отзывы: