Complete the Job - 186
JT100/JT100 All Terrain Operator’s Manual
Antifreeze Drilling Unit
Antifreeze Drilling Unit
Your drilling unit can be left overnight in freezing conditions by circulating a polyproplyene-based antifreeze
(p/n 265-644) through unit before shutdown.
1.
Fill antifreeze tank with 27 gal (102 L) of approved antifreeze.
2.
Install plug on suction side of drilling fluid pump.
3.
Open valve (3) between antifreeze tank and drilling fluid pump.
4.
Open valves under water pressure gauges in cab (1) and on fluid pump (2).
5.
Turn drilling fluid potentiometer counterclockwise to zero position.
6.
Start unit and set throttle to slow position.
7.
Set drilling fluid pump switch to on position.
8.
Slowly turn drilling fluid potentiometer clockwise until indicator light comes on.
9.
Run drilling fluid pump until antifreeze comes out of spindle.
10. Turn drilling fluid pump switch to off position.
11. Close valve (1) between antifreeze tank and drilling fluid pump.
12. Close water pressure gauge valves (1,2).
j28om130t.eps
1
2
3
Содержание JT100
Страница 1: ...JT100 JT100 All Terrain Tier 4 Issue 2 1 Original Instruction Operator s Manual 053 2814...
Страница 23: ...Safety 22 JT100 JT100 All Terrrain Operator s Manual Machine Safety Alerts Machine Safety Alerts...
Страница 105: ...Prepare 104 JT100 JT100 All Terrain Operator s Manual...
Страница 193: ...Service 192 JT100 JT100 All Terrain Operator s Manual Service and Lubrication Overview Service and Lubrication Overview...
Страница 247: ...Service 246 JT100 JT100 All Terrain Operator s Manual As Needed...
Страница 254: ...JT100 JT100 All Terrain Operator s Manual Service Record 253 Service Record Service Performed Date Hours...
Страница 255: ...Service Record 254 JT100 JT100 All Terrain Operator s Manual Service Performed Date Hours...
Страница 258: ......
Страница 259: ......
Страница 260: ...JT100 JT100 All Terrain Operator s Manual Appendix 259 Appendix Chapter Contents Engine Diagnostic Codes...