![Direction Plus Ford Ranger PX Direction Plus ProVent 150 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/direction-plus/ford-ranger-px-direction-plus-provent-150/ford-ranger-px-direction-plus-provent-150_installation-manual_2507481006.webp)
Direction-
Plus™
PLPV621DPK_Install
Page | 6
This image shows how the ProVent® Lines are to be assembled
9.
Mount one end of the first 650mm long 19mm (3/4
”)
hose to the lower 19mm (3/4
”)
fitting on the ProVent 150. Secure
with hose clamp.
10.
Mount the other end of the same 650mm long 19mm (3/4
”)
hose to the 19mm (3/4
”) 90˚
joiner fitting on the hose
connected to the
engine head on the front driver’s
side. Secure with hose clamp.
11.
Mount one end of the second 650mm 19mm (3/4
”) hose to the u
pper 19mm (3/4
”)
fitting on the ProVent 150. Secure
with hose clamp.
12.
Mount the other end of the second 650mm 19mm (3/4
”)
hose to the 19mm (3/4
”) 90˚ joiner fitting on the hose
connected to the hose running to the black box in front of the intercooler on the front passenger side. Secure with hose
clamp.
Hose configuration in PX Ranger with ProVent® 150 installed
–
Note, the hose to the ProVent® need to be run underneath the hard
pipe in order to fit the engine cover back on, the hoses are long enough to allow for this. (hose clamps not shown)
19mm (3/4
”) Supply h
ose to bottom
port on ProVent® 150, from engine
19mm (3/4
”) Return h
ose to air
intake, from top port on ProVent®
150