Direct Supply Panacea 1000-FLEX Bed  

Standard Features

80" Mattress Support Platform

8" to 28" Travel Range

Quiet DC Actuators

Welded Tubular Frame

Grid Sleep Surface

Wide Stable Base

SoftTone Frame Color

Heavy-Duty Casters

Locking System:

• Roll-in-Low Lock System

• Roll at any Height Mobility

Baseboard Bumper

Mattress Stops

Electrical Specifications

Power:

120V

Frequency:

60Hz

Current Rating:

4.8 Amps

Classification:

Class I, Type B

Mode of Operation:

10% Maximum Duty Cycle

2 minutes on/18 minutes off

Circuit Protection:

Auto reset current sensors

Environmental Conditions

Operating Conditions

:

Ambient Temperature: +10°C to +35°C

Relative Humidity: 30% to 75% Non-Condensing

Atmospheric Pressure: 700 hPa to 1060 hPa

Protected Against Splashing Water IPX4

Storage and Shipping Conditions

:

Ambient Temperature: -40°C to +70°C

Relative Humidity: 10% to 100%

Atmospheric Pressure: 500 hPa to 1060 hPa

Mechanical Specifications

Description: Dimensions:

Overall Dimensions .............. 86.9"L x 35.0"W x 8.75"H
Weight - Total without Panels ...............145 lb (65.8 kg)
Weight - Head Frame ........................... 67.3 lb (30.5 kg)
Weight - Foot Frame ............................ 77.7 lb (35.2 kg)
Maximum Back Angle .........................65° to horizontal
Maximum Knee Angle ........................25° to horizontal
Maximum Height Mattress 
Support Platform .................................28" Above Floor
Minimum Height Mattress 
Support Platform ...................................8" Above Floor
Safe Working Load ............................. 450 lb (204.1 kg)
Maximum Patient Weight ...................400 lb (181.4 kg)

Locating Your Serial Number

The serial number label is located at the foot end of the 

bed, on the bed frame under the mattress support deck.

Conform To:

AAMI STD ES60601-1

IEC STD 60601-1

IEC STD 60601-2-52

Certified to CSA STD C22.2 # 60601-1

I.D. Label Symbol Definition

Attention
Consult accompanying documents

Safe Working Load

Maximum Patient Weight

Type B Applied Parts, user controls, mattress, 

support platform
Class II Equipment

 

Protective Earth (ground)

Pinch Point

Features and Specifications

 

Содержание Panacea 1000-FLEX BED

Страница 1: ...uipment Furnishings Please read this entire guide carefully and keep it for future reference This guide will provide you with instructions warnings warranty informa tion and other important informatio...

Страница 2: ...wall mounted outlet in good working order with no cracks or chips The plug should fit tightly into the outlet The ground pin should be intact and secure Do not use power strips extension cords or mult...

Страница 3: ...tient by a qualified clinician or medical provider to ensure maximum safety of the resident patient The assessment should be conducted within the context of and in compliance with the state and federa...

Страница 4: ...as should be used no closer than 30 cm 12 inches to any part of the Direct Supply Panacea 1000 FLEX bed including cables specified by the manufacturer Otherwise degradation of the performance of this...

Страница 5: ...C to 70 C Relative Humidity 10 to 100 Atmospheric Pressure 500 hPa to 1060 hPa Mechanical Specifications Description Dimensions Overall Dimensions 86 9 L x 35 0 W x 8 75 H Weight Total without Panels...

Страница 6: ...igure 3 2 Remove the screws using the 2 Phillips screwdriver do not discard the screws 3 Position and insert the mattress stops in the holes provided Figure 4 Reinstall the screws removed in step 2 4...

Страница 7: ...soft surface front face down 3 Foot panel brackets are shorter of two sizes Figure 5 4 Install the foot panel brackets with four screws provided Bracket offset should face up Figure 6 Do not tighten...

Страница 8: ...ant Route one cable under the control box and plug into pendant port Route the second cable under the control box and connect to the hand pendant Figure 9 4 Route the two cables under the main frame t...

Страница 9: ...from contacting floor This will help prevent cord damage when transporting bed CAUTION If a power cord is damaged remove bed from service until repairs are performed WARNING Possible Injury Before lea...

Страница 10: ...foot frame by compatible ID labels on left side Figure 16 2 Lay frame halves on soft surface feet side down Place packing material under head frame to make assembly easier Figure 17 Ensure the split f...

Страница 11: ...amage to the actuators 3 Install the back actuator and knee actuator on the head frame and foot frame as shown using the actuator pin and clip Figure 19 4 Insert head frame into foot frame and line up...

Страница 12: ...23 Figure 24 1 Line up back and knee actuators and insert actuator pin then add clip to lock in place Figure 22 and 23 Ensure the washers are used on the back actuator Figure 24 Figure 22 Split Frame...

Страница 13: ...hen route behind cable bundle Figure 25 and 26 3 Insert back actuator cable in port 1 and insert hi lo actuator head end cable in port 3 Figure 27 4 Secure cables with cable clamp Figure 28 5 Route po...

Страница 14: ...tuators and control box contain no serviceable parts Overload protection is achieved via current sensing technology which will automatically reset If any bed function fails to operate check to see if...

Страница 15: ...wer cord to frame Tape remaining cables in their original position It is very important to keep actuator cables routed along frame in original factory installed positions If this step is not followed...

Страница 16: ...he bed is plugged into power source and control box green light is illuminated 4 Thermal overload condition This should self correct in 2 minutes or less Do not surpass 10 duty cycle 2 min on 18 min o...

Страница 17: ...yclable items properly To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources CAUTIO...

Страница 18: ...to disconnect from bed resulting in loss of control of bed 4 Take extra care when moving bed remember do not move bed while occupied by resident patient on any sloped surface Moving a bed on a sloped...

Страница 19: ...1 800 634 7328 for instructions 3 Install the trapeze assembly onto the trapeze adapter according to the trapeze manufacturer s instructions 4 Operate the bed from its highest through lowest position...

Страница 20: ...FLEX bed is intended for use in an electromagnetic environment for professional healthcare in which radiated RF disturbances are controlled The customer or the user of the Direct Supply Panacea 1000 F...

Страница 21: ...61000 4 5 0 5 kV 1 kV line s to line s 0 5 kV 1 kV 2 kV line s to earth 0 5 kV 1 kV line s to line s 0 5 kV 1 kV 2 kV line s to earth Mains power quality should be that of a typical professional heal...

Страница 22: ...kHz Portable and mobile RF communications equipment should be used no closer to any part of the Direct Supply Panacea 1000 FLEX bed including cables than the recommended separation distance calculate...

Страница 23: ...e to someone else or at the end of the applicable limited warranty period identified below whichever is earlier Warranty Period Parts Only Welds 15 years Mechanical Components 3 years Electronics 3 ye...

Страница 24: ...Distributed by Direct Supply Manufacturing Inc 7301 W Champions Way Milwaukee WI 53223 2021 Direct Supply Manufacturing Inc All Rights Reserved Direct Supply Panacea and all associated logos are the...

Отзывы: