3
•
Electromagnetic disturbance is reduced due to high frequency
being involved only during the arc ignition phase.
•
“Energy Saving” function to operate the power source cooling
fan and the torch water cooling only when necessary.
•
Low absorbed current consumption.
•
TIG
- Excellent TIG welding characteristics.
- High frequency arc striking of TIG welding, precise and effi-
cient even from long distance.
- Using special TIG torches allows remote adjustment of weld-
ing current directly from the torch.
- Standard built-in pulsation (from 0,5 to 2000 Hz) with provi-
sion for entering the SYN Pulse function.
•
MMA
- The VRD (Voltage Reduction Device) can be activated, which
reduces voltages to below 12 V, which means that the weld-
ing power source can be used in ambient conditions in which
there is a high electrical risk, thereby providing maximum op-
erator safety.
- “Arc Force” adjustable to select the best dynamic charac
teristics for the welding arc.
- “Hot Start” adjustable to improve ignition with particularly
difficult electrodes.
- Anti-sticking function to avoid the electrodes sticking.
DIX TIG GO 1906.M HF
•
The PFC device makes the wave form of the current absorbed
sinusoidal, which results in no harmonic disturbance on the
mains and optimisation of absorption, which allows you to use
the welding power source’s full power with a 16 A fuse, as well as
ensuring greater protection of the welding power source against
fluctuations in the power supply voltage.
DIX TIG GO 2506.M HF
•
Suitable for use on all robotic systems.
•
Optional automation interface that handles all process start/
stop signals, regulation of the principal welding parameters, and
also acts as a flexible, efficient interfacing system that meetsall
Analogue / Digital connection requirements.
Usage limits (IEC 60974-1)
The use of a welder is typically discontinuous, in that it is made up
of effective work periods (welding) and rest periods (for the posi-
tioning of parts, the replacement of wire and underflushing opera-
tions etc.) This welder is dimensioned to supply a I
2
max nominal
current in complete safety for a period of work of X% of the total
usage time. The regulations define the total usage time to be 10
minutes. The work cycle is considered to be X% of this period of
time. If the permitted work cycle time is exceeded, an overheat
cut-off occurs to protect the components around the welder from
dangerous overheating. Activation of thermal protection is signaled
by “t° C” flashing on control panel display (for further information
see the control panel manual). After several minutes the overheat
cut-off rearms automatically and the welder is ready for use again.
Technical data
The general technical data of the system are summarized in ta-
ble 1.
How to lift up the welding power source
The welding power source has a strong handle all in one with the
frame, used for transporting the welding power source manual-
ly only.
NOTE: These hoisting and transportation devices conform to Eu-
ropean standards. Do not use other hoisting and transportation
systems.
Table 1
Model
DIX TIG GO 1906.M HF
DIX TIG GO 2506.M HF
TIG
MMA
TIG
MMA
Power supply 50/60 Hz
V
1~ 230 ±20%
3~ 400 ±20%
Power supply: Z
max
Ω
(*)
0,092
Input power @ I
2
Max
kVA
6,0
6,6
9,1
9,8
Delayed fuse (I
2
@ 100%)
A
16
10
Power factor / cosφ
0,99/0,99
0,96/0,99
0,95/0,99
Efficiency degree
η
0,77
0,80
0,78
0,83
Open circuit voltage
V
100
100
Current range
A
5÷220
10÷180
5÷300
10÷270
Duty cycle @ 100% (40°C)
A
160
120
210
200
Duty cycle @ 60% (40°C)
A
190
150
250
230
Duty cycle @ X% (40°C)
A
220
(30%)
180
(30%)
300
(35%)
270
(35%)
Usable electrodes
mm
1,2÷2,4
1,6÷4,0
1,2÷4,0
1,6÷5,0
Standards
IEC 60974-1 • IEC 60974-3 • IEC 60974-10
Protection class
IP 23 S
IP 23 S
Insulation class
F
F
Dimensions
mm
465 - 390 - 185
495 - 390 - 185
Weight
kg
14
17,5
IMPORTANT:
These systems, tested in accordance with the requirements of the
EN/IEC 61000-3-3
standard, satisfy the requirements laid down by the
EN/
IEC 61000-3-11
standard.
DIX TIG GO 1906.M HF
(*) This equipment meets the requirements laid down in the
EN/IEC 61000-3-12
standard on harmonic currents.
DIX TIG GO 2506.M HF
This equipment complies with
EN/IEC 61000-3-12
provided that the maximum permissible system impedance Z
max
is less than or equal to 0,092
at the interface point between the user’s supply and the public system. It is the responsibility of the installer or user of the equipment to ensure,
by consultation with the distribution network operator if necessary, that the equipment is connected only to a supply with maximum permissible
system impedance Z
max
less than or equal to 0,092.