![DINSEO DIX TIG GO 1906.M HF Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/dinseo/dix-tig-go-1906-m-hf/dix-tig-go-1906-m-hf_operation-manual_2505866021.webp)
21
To exit the setting phase, hold the WELDING PARAMETERS
SELECTION key (T7) down for about
1
second.
2B) FAST PULSE
TIG pulse welding with manual setting of parameters.
Press the PULSE key (T3) until the requited pulsation
is active.
Press the WELDING PARAMETERS SELECTION
Key (T7) a number of times to set the following (in
addition to the WELDING PARAMETERS defined as
being “BASIC”):
L19
BASE CURRENT I
b
1906.M HF
2506.M HF
5 ÷ 220 A
5 ÷ 300 A
L20
PEAK CURRENT I
p
1906.M HF
2506.M HF
5 ÷ 220 A
5 ÷ 300 A
L22
PULSATION FREQUENCY f
1906.M HF - 2506.M HF
FAST
0,5 ÷ 500 Hz
To exit the setting phase, hold the WELDING PARAMETERS
SELECTION key (T7) down for about
1 second
.
2C) ULTRA FAST PULSE
TIG pulse welding with manual setting of parameters.
The possibility of using pulsation frequencies that
are not as high, up to 2000 Hz, ideal for welding
minor thicknesses, makes it possible to achieve a great
reduction in the arc cone and the area thermally
altered, with a more stable, concentrated arc and an
increase in weld penetration and speed.
I (A)
t
I (A)
t
Press the PULSE key (T3) until the requited pulsation is active.
Press the WELDING PARAMETERS SELECTION Key (T7) a
number of times to set the following (in addition to the WELDING
PARAMETERS defined as being “BASIC”):
PULSE
SYN
FAST
SLOW
T5
PULSE
SYN
FAST
SLOW
T3
L19
L20
L22
T7
L19
BASE CURRENT I
b
1906.M HF
2506.M HF
5 ÷ 220 A
5 ÷ 300 A
L20
PEAK CURRENT I
p
1906.M HF
2506.M HF
5 ÷ 220 A
5 ÷ 300 A
L22
PULSATION FREQUENCY f
1906.M HF - 2506.M HF
ULTRA FAST
500 ÷ 2000 Hz
To exit the setting phase, hold the WELDING PARAMETERS
SELECTION key (T7) down for about
1 second
.
2D) SYN PULSE
TIG pulse welding with synergic setting of parameters.
Press the PULSE key (T3) until the requited pulsation
is active.
Press the WELDING PARAMETERS SELECTION
Key (T7) a number of times to set the following (in ad-
dition to the WELDING PARAMETERS defined as
being “BASIC”):
L19
BASE CURRENT I
b
1906.M HF
2506.M HF
25 ÷ 220 A
25 ÷ 300 A
This function, which is good for less skilled operators, makes it
possible to change the pulsation parameter (Peak current
I
p
) and
the other values for the corresponding pulsation parameters (Base
current
I
b
- Pulsation frequency
f
) vary automatically.
To exit the setting phase, hold the WELDING PARAMETERS
SELECTION key (T7) down for about
1 second
.
PULSE
SYN
FAST
SLOW
T3
Содержание DIX TIG GO 1906.M HF
Страница 5: ...5 FIG A ...
Страница 10: ...10 Wiring diagram DIX TIG GO 1906 M HF ...
Страница 11: ...11 2101WA31 ...
Страница 12: ...12 Wiring diagram DIX TIG GO 2506 M HF ...
Страница 13: ...13 2101WB24 ...