4
How to lift up the system
Strap the system safely and securely in the slings working from
the bottom, then lift up from the ground.
This welding welding power source has a robust handle built
into the frame for moving the equipment.
NOTE:
These hoisting and transportation devices conform to
European standards. Do not use other hoisting and transpor
-
tation systems.
Opening the packaging
The system essentially consists of:
•
DIX PI 3506.M I / DIX PI 3006.M I Puls / DIX PI 3506.M I
Puls
weld unit.
•
Separately:
- MIG-MAG welding torch (optional).
- Coolant unit for welding torch (optional).
- Trolley to carry it around (optional).
Perform the following operations on receiving the apparatus:
•
Remove the welding power source and all accessories and
components from the packaging.
•
Check that the welding apparatus is in good condition; other-
wise immediately inform the retailer or distributor.
•
Check that all the ventilation grilles are open and that there
is nothing to obstruct the correct air flow.
Installation and connections
The installation site for the system must be carefully chosen
in order to ensure its satisfactory and safe use. The user is re-
sponsible for the installation and use of the system in accord-
ance with the producer’s instructions contained in this manual.
Before installing the system the user must take into consider-
ation the potential electromagnetic problems in the work area.
In particular, we suggest that you should avoid installing the
system close to:
•
Signalling, control and telephone cables.
•
Radio and television transmitters and receivers.
•
Computers and control and measurement instruments.
•
Security and protection instruments.
Persons fitted with pace-makers, hearing aids and similar
equipment must consult their doctor before going near a weld-
ing power source in operation. The equipment’s installation
environment must comply to the protection level of the frame.
The welding unit is characterized by the following classes:
•
IP 23 S protection class indicates that the welding power
source can be used in both interior and exterior environ-
ments.
•
The “S” usage class indicates that the welding power source
can be employed in environments with a high risk of electri-
cal shocks.
This system is cooled by means of the forced circulation of air,
and must therefore be placed in such a way that the air may
be easily sucked in and expelled through the apertures made
in the frame.
Assemble the system in the following way:
•
Assemble the trolley.
•
Fixing the cooling unit to the trolley.
•
Fixing of the welding welding power source to the trolley and
the cooling unit (electrical and plumbing connections).
•
Connect up the welder to the mains.
•
Connect up the welding cables.
Instructions for fitting the individual components / optional ex-
tras are contained in the relevant packaging.
Connection to the electrical supply
Connection of the welding power source to the user line
(electrical current) must be performed by qualified per-
sonnel.
Before connecting the welding welding power source to
the mains power supply, make sure that rated voltage and
frequency correspond to those provided by the mains pow-
er supply and that the welding welding power source’s
power switch is turned to “O”.
Use the welder’s own plug to connect it up to the main pow-
er supply. Proceed as follows if you have to replace the plug:
•
3 conducting wires are needed for connecting the welding
power source to the supply.
•
The fourth, which is YELLOW GREEN in colour is used for
making the “GROUND” connection.
Before connecting the welding welding power source to
the mains power supply, make sure that rated voltage and
frequency correspond to those provided by the mains pow-
er supply and that the welding welding power source’s
power switch is turned to “O”.
Table 2 shows the capacity values that are recommended for
fuses in the line with delays.
NOTE:
Any extensions to the power cable must be of a suita
-
ble diameter, and absolutely not of a smaller diameter than the
special cable supplied with the welding power source.
Table 2
Model
DIX PI 3006.M I
DIX PI 3506.M I
DIX PI 3006.M I Puls
DIX PI 3506.M I Puls
MIG-MAG welding
Input power @ I
2
Max
kVA
13
17,8
17
23,7
Delayed fuse (I
eff)
A
16
20
25
25
Nominal current @ 40% duty cycle (40°C)
A
320
400
320
400
Mains cable
Length
Cross section
m
mm
2
4
4 × 2,5
4,5
4 × 4
4
4 × 2,5
4,5
4 × 4
Ground cable cross section
mm
2
50
50
50
50
Содержание DIX PI 3006.M I Puls
Страница 12: ...12 2101AC34 DIX PI 3006 M I DIX PI 3506 M I...
Страница 13: ...13 2101AC33 DIX PI 3006 M I Puls DIX PI 3506 M I Puls...