21
Menu SPECIAL FUNCTIONS
From the
SEtUP
menu, push the
PRG
key (T5) for more than 3
seconds to access the SPECIAL FUNCTIONS menu, which pro-
vides access to additional functions that can only be managed
by an expert, responsible operator. The two displays (D1-D2) will
read
SPC FnC
.
D1
D2
T5
T ≥ 3 s
SAFETY CALIBRATION CODE (SCC)
ATTENTION:
This operation, if carryed on, optimizes the effi
-
ciency of the welding circuit (only in MIG welding processes).
To set the length of the welding circuit (adjustable from 1 to 100
m) follow this procedure:
•
Rotate the ENCODER knob - A (E1) until obtaining on the PA-
RAMETER DISPLAY screen - A (D1) and the writing
SCC
.
•
Rotate the ENCODER knob - V (E2) until obtaining on the PA-
RAMETER DISPLAY screen - V (D2) the desired number.
CAUTION:
The operation does not require confirmation!
CAUTION:
The data inserted is valid for all the MIG welding pro
-
cesses.
Example:
Length of cable mass 3 m.
Length of welding torch cable 3 m.
The overall length of the welding circuit is 6 m (6 is the number that
will therefore be inserted).
D1
D2
E2
E1
MOTOR CALIBRATION (Mot CAL)
ATTENTION: This procedure allows you to calibrate the wire
speed (only in MIG welding processes).
Proceed as follows:
•
Rotate the ENCODER - A (E1) knob until the PARAMETER DIS-
PLAY - A (D1) screen reads
Mot CAL
.
D1
E1
•
To open the CALIBRATION menu, push the PRG key (T5).
T5
•
The procedure of calibration is carried out in 3 different phases:
1.
Calibration parameter SM1 (MINIMUM SPEED)
Push and release the torch button, and then wait for the
wire to stop automatically, and the
End MiS
message to ap-
pear. Measure (in cm) the dangling wire and insert the value
shown, in the software of the welder, by means of the rota-
tion of the ENCODER knob - V (E2) appearing on the PA-
RAMETER DISPLAY screen - V (D2) is the desired value.
D1
D2
E2
2.
Calibration parameter SM2 (MEDIUM SPEED)
Then turn the ENCODER - A knob (E1) until the PARAM-
ETER DISPLAY - A screen (D1) shows the
SM2
parame-
ter. Push and release the torch button, and then wait for the
wire to stop automatically, and the
End MiS
message to ap-
pear. Measure (in cm) the dangling wire and insert the value
shown, in the software of the welder, by means of the rota-
tion of the ENCODER knob - V (E2) appearing on the PA-
RAMETER DISPLAY screen - V (D2) is the desired value.
D1
D2
E2
E1