Start the welding power source by pressing the switch, located on
the back panel, at the position
I
.
1 - WELDING PROCESS SELECTION
Select the MIG-MAG manual PROCESS of welding, pressing and
releasing, even various times if necessary, the WELDING PRO-
CESS SELECTION key (T2) until the corresponding LED lights up.
T2
Push the SELECT PROGRAM key (T5). The corresponding LED
switches on.
T5
To access the MIG-MAG welding process: rotate the ENCODER
knob - A (E1) until obtaining on the PARAMETER DISPLAY screen
- A (D1) and the writing
MAn
.
E1
2 - WELDING MODE SELECTION
Select the MODE of welding, pressing and releasing, even various
times if necessary, the WELDING MODE SELECTION key (T3)
until the corresponding LED lights up.
1
2
3
4
5
6
T3
1. TWO STROKE (2T)
2. FOUR STROKE (4T)
3. CRATER 2T
4. CRATER 4T
5. SPOT WELDING 2T
6. STITCH WELDING 2T
3 - SPECIAL FUNCTIONS “Fx” SELECTION
The SPECIAL FUNCTIONS “Fx” that are only available in the
MIGMAG manual welding process are shown below. For all the
other explanations regarding this menu make reference to the rel-
ative paragraph.
•
PRE GAS (PrG) -
Provides an additional quantity of gas for a
defined time, before welding starts.
•
STARTING SPEED (StS) -
Regulates the speed at which the
wire approaches the workpiece. The value indicated is a percent-
age variation in relation to the factory setting value.
•
HOT START (HoT) -
Regulates the current intensity for igniting
the welding arc. The value indicated is a percentage variation
in relation to the factory setting value.
•
CRATER START SPEED (F08) -
Sets the initial speed of the
welding wire for the crater.
•
CRATER START VOLTAGE (F09) -
Sets the initial welding volt-
age for the crater.
•
CRATER START TIME (F10) -
This function defines the time
in which the current remains at the value of CRATER START
SPEED or CRATER START VOLTAGE.
•
CRATER START SLOPE (F11) -
Time taken to go from the CRA-
TER START SPEED or CRATER START VOLTAGE level to the
welding speed or voltage level.
•
CRATER END SLOPE (F12) -
Time required to go from the
welding speed or voltage level to the CRATER END SPEED or
CRATER END VOLTAGE level.
•
CRATER END SPEED (F13) -
Sets the final speed of the weld-
ing wire for the crater.
•
CRATER END VOLTAGE (F14) -
Sets the final welding volt-
age for the crater
•
CRATER END TIME (F15) -
This function defines the time in
which the current remains at the value of CRATER END SPEED
or CRATER END VOLTAGE.
•
SPOT WELD TIME (F07) -
The time during which spot welding
takes place after the arc is ignited, after which the arc is extin-
guished automatically.
•
STITCH WELD TIME (F05) -
Time in which the welding in tracts
is performed after the ignition of the arch, after which the arch
switches off automatically.
•
STITCH WELD PAUSE (F06) -
Time of pause between one
welding in tracts and another.
•
BURN BACK (bUb) -
Regulates the length of the wire after weld-
ing. The value indicated is a percentage variation in relation to
the factory setting value. Higher numbers correspond to more
burning of the wire.
•
POST GAS (PoG) -
Provides an additional quantity of gas for a
defined time, after welding ends.
•
SWITCH WIRE SPEED (F19) -
Sets the speed for SWITCH
welding (only available if SWITCH is enabled in the SETUP).
•
SWITCH VOLTAGE (F20) -
Sets the voltage for SWITCH weld-
ing (only available if SWITCH is enabled in the SETUP).
■
PROGRAM DEFAULT (dEF)
WARNING:
If carried out, this operation resets the program
in use to the factory default settings.
To carry out the reset of the settings / parameters, proceed in the
following manner:
•
Rotate the ENCODER - A (E1) knob until both the displays read
dEF no
(see figure).
E1
•
Rotate the ENCODER - V knob (E2) until the PARAMETERS
DISPLAY - V screen (D2) reads
YES
.
D2
E2