55
Optimized layout for A4 print.
TYPE
A
888888
diaG
D
adC.uv
ADC.pnt
prG.ver
ser.num
displa
keyb
4
5
1
15
8
9
USER_MAN_ENG_DGT100_V8
Diagnostics
Display of the µV related to the weight on the scale.
Use the and keys to display the different channels (in
dep.Ch
mode the sum is also visible).
Display of firmware release (e.g.
08.04.00
).
Display of indicator serial number.
Activation of all display segments and indicators.
Display of the A/D points of the converter related to the weight on the scale.
Use the and keys to display the different channels (in
dep.Ch
mode the sum is also visible).
For correct operation, the value of A/D points must be stable, and increase if a load is applied to the cell.
For correct operation, the value of the µV of each channel must be less than 30000 with a weight equal to the maximum capacity.
This value must be stable, and increase if a load is applied to the cell.
Firmware release
Serial number
Display
Keypad
Cells / converter test
Press the same key 3 consecutive times to exit.
The code of last key pressed is shown on the display:
8001
8002
8003
8004
80AA