5
Figure 4.7 Schematic diagram of connection of large screen display
Note: Two large screens can also be connected in parallel, for example, the two
input lines of two large screens can be connected in parallel in the left figure.
4.4 Connection method of load cell
The sensor interface of this instrument is RS485 communication port. The power supply is 12V,
the driving current is > 400mA, and 16 digital sensors can be connected. If ADJ and V- are
shorted, the power supply voltage of the sensors can be increased to adapt to the longer
connection distance.
4.4.1 Label and function of load cell interface
serial
number
grade
Corresponding function
1
V+
Sensor positive supply
2
V+
Sensor positive supply
3
485A
485A
4
485B
485B
5
V-
Negative sensor supply
6
V-
Negative sensor supply
7
ADJ
If the adj and v-short circuit can improve the supply
voltage of the sensor
[