42
Bit 15
Output relay OUT19 status
Bit 16
Output relay OUT20 status
4x0200
Output value of analog quantity (4-20mA)
2 bytes, unsigned,
read-only
4x0201
Last stored item
2 bytes, unsigned,
read-only
4x0202
Net weight of scale 1
4 bytes, signed,
read-only
4x0204
4 bytes, signed,
read-only
4x0206
Gross weight of scale 1
4 bytes, signed,
read-only
4x0208
4 bytes, signed,
read-only
4x0210
Current AD value of scale No.1
4 bytes, unsigned,
read-only
4x0212
Panel number (see Note 3 for details)
2 bytes, unsigned,
read/write
4x0213
Accumulated times of storage
2 bytes, unsigned,
read/write
4x0214
Division value
2 bytes, unsigned,
read/write
4x0215
Low byte: weight decimal places, high
byte: flow decimal places.
2 bytes, unsigned,
read/write
Modbus RTU function code table (continued 1)
Functional
address
meaning
Register attribute
4x0216
Zero range
2 bytes, unsigned,
read/write
4x0217
Zero tracking range
2 bytes, unsigned,
read/write
4x0218
Recipe number (formerly process number)
2 bytes, unsigned,
read/write
4x0219
Judging the scope of stability
2 bytes, unsigned,
read/write
4x0220
Calibration coefficient of scale No.1
4 bytes, unsigned,
read/write
4x0222
Accumulated weight of stored
4 bytes, unsigned,
read/write
4x0224
Zero point calibration AD value of No.1
scale
4 bytes, unsigned,
read/write