Operation

1.  Room Temperature 

Displays current  ambient tem-

perature in the room.

2.  Set Temperature 

Displays and controls the heater 

to the temperature at which the  

thermostat is currently set to.  

Press 

8

 to lower the thermostat 

and press 

9

 to raise the thermo-

stat.  Pressing both 

8

 and 

9

 to-

gether will toggle between Celsius 

and Fahrenheit.

3.  Flame Effect Icon

The flame icon will flicker if and 

when the Flame Effect is turned 

on.  Press 

11

 to turn the Flame 

Effect on, and press 

10

 to turn the 

Flame Effect off.

4.  Purifire™ Icon

The display arrows for the Puri-

fire

™ 

will cycle when turned on.  

Press 

13

 to turn the Purifire™ 

function on, and press 

12

 to turn 

Purifire™ off.

!

 NOTE:

  The Purifire™ function 

on this device will control only 

those units with the Purifire™ 

installed.

5.  Heat Off Indicator

This function manually overrides 

the thermostat control and pre-

vents the fireplace’s heater from 

coming on.
To do this, press 

8

 to decrease 

Set Temperature to any tem-

perature below 0

C or 32

F. To 

reactivate heat from “

HEAT OFF

” 

setting, press 

9

 to increase the 

thermostat Set Temperature.  The 

Set Temperature will be displayed 

starting at 21

o

 C (70

o

 F), replacing 

the “

HEAT OFF

” icon.

6.  Function Lock Indicator

Enabling this function will lock out 

the Wall Switch Remote Control 

so as to prevent the current set-

tings from being changed.  To 

Enable, press 

8

9

, and 

10

 se-

quentially.  To disengage, press 

8

9

 and 

10

 sequentially again.  The 

Indicator icon will be displayed 

when enabled.

Содержание WRCPF-KIT

Страница 1: ...ad this manual first before attempting to install or use this device For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or prop...

Страница 2: ...ich if not carefully followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose the user to the risk of fire serious injury or death...

Страница 3: ...roubleshooting and Technical Support OR Toll Free 1 888 DIMPLEX 1 888 346 7539 Monday to Friday 8 00 a m to 4 30 p m EST In order to better serve you please have your model and serial number ready or...

Страница 4: ...e designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Страница 5: ...where the manual controls were plugged in to Figure 1 Manual Controls Screws 3 Pull front edge of plastic em ber bed grate up and forward until rear tab releases from the ledge located at the bottom o...

Страница 6: ...bly 9 Install the two 2 screws removed in step 4 into the remote control bracket and attach it to the fireplace 10 Replace the log set by insert ing front edge and pushing the back down until rear tab...

Страница 7: ...standard device box and should the hard wire installation method be chosen a location near an available 24V power source should be considered WARNING Electrocution or other bodily harm and property da...

Страница 8: ...by realigning the tracks on the top and bottom of the unit with the guides inside the Outer Housing Push the Controller in until you hear the push lock latches click Figure 8 6 Slide the Controller an...

Страница 9: ...V door bell circuit or a Class 2 24V transformer The 24V wire leads coming into the device box should have between 4 and 6 inches 10 15 cm of slack left inside the box to allow for ease of installatio...

Страница 10: ...r make sure orientation is as shown as in Figure 11 5 Replace the wire lead storage Figure 10 Figure 11 compartment cover on the Controller with wire leads fed through and exposed 6 Feed the two wire...

Страница 11: ...Locking screws Outer Housing tions NOTE Wire leads are not polarized due to the nature of this device 9 Coil excess wiring to the back of the device box and insert the Controller and Outer Hous ing i...

Страница 12: ...l Control Installation Figure 15 Ensure each of the two Controller lead wires are connected to separate Low Voltage 24V only wires Low Voltage 24V power source ONLY Controller wire leads Figure 16 Fla...

Страница 13: ...econds BLF34 BLF50 BLF74 Models 1 Ensure that power is supplied through main service panel 2 Inside the fireplace turn Main On Off Switch to Off Figure 18 A and wait 10 seconds 3 Move the Three Positi...

Страница 14: ...effect only twice activates Level 2 flame effect and Purifire three times activates Level 3 flame effect Purifire and heat B Off Button Pressing this button at any time will shut the unit off C Manua...

Страница 15: ...2 4 6 7 9 11 8 10 12 13 14 1 Room Temperature 2 Set Temperature 3 Flame Effect 4 Purifire 5 Heat Off Indicator 6 Function Lock Indicator 7 RF Code Function Indicator 8 Set Temperature Down 9 Set Temp...

Страница 16: ...unction on and press 12 to turn Purifire off NOTE The Purifire function on this device will control only those units with the Purifire installed 5 Heat Off Indicator This function manually overrides t...

Страница 17: ...ries are low and should be replaced To further extend battery life the LED backlighting is turned off when the Low Battery Indicator is displayed Other Functions 6 Hour Sleep Timer This feature ensure...

Страница 18: ...t dealer or other person is authorized to give any warranties on behalf of Dimplex The customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product...

Отзывы: