EN-8
English
11
11 Device Information
1
Type and order code
LA 14PMS
2
Design
2.1
Controller, external
External
2.2
Thermal energy metering
---
2.3
Installation location / degree of protection according to EN 60 529
Outdoor / IP 24
2.4
Frost protection condensate tray / heating water
1
1. The heat circulating pump and the heat pump controller must always be ready for operation.
Heated / yes
2.5
Performance levels
2
3
Operating limits
3.1
Heating water flow
2
/ return
°C
2. At air inlet temperatures of -25 °C to -10 °C flow temperature rising from 50 °C to 65 °C
up to 65 ± 2 / from 18
3.2
Air (heat source)
°C
-25 to +35
4
Performance data / flow rate
3
3. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, start-up and operation can be
found in the respective sections of the installation and operating instructions.
The specified values have the following meaning, e.g. A7 / W35: Heat source temperature 7 °C and heating water flow temperature 35 °C.
4.1
Heating water flow rate / internal pressure differential
maximum
m³/h / Pa
2.4 / 10100
minimum
m³/h / Pa
1.0 / 3200
4.2
Heat output / COP
4
4. With minimum heating water flow.
EN 14511
at A7 / W35
kW / ---
8.0 / 2.5
kW
/
---
4.0 / 2.0
at A2 / W35
kW / ---
10.2 / 3.1
kW / ---
5.8 / 2.9
at A7 / W35
kW / ---
13.3 / 3.6
kW / ---
7.4 / 3.7
at A7 / W55
kW / ---
11.7 / 2.8
kW / ---
6.3 / 2.6
at A10 / W35
kW / ---
14.5 / 3.9
kW / ---
8.1 / 4.0
4.3
Sound power level according to EN 12102
dB(A)
63
4.4
Sound pressure level at a distance of 10 m
(air outlet side)
5
dB(A)
5. The specified sound pressure levels correspond to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
35
4.5
Air flow
m³/h
4500
5
Dimensions; weight and filling quantities
5.1
Device dimensions without connections
6
H x W x L cm
6. Note that additional space is required for pipe connections, operation and maintenance.
1571 x 852 x 1552
5.2
Device connections for heating system
Inches
R 1 1/4"
5.3
Weight of the transportable unit(s) incl. packaging
kg
256
5.4
Refrigerant; total filling weight
type / kg
R290 / 1.8
5.5
Lubricant; total filling quantity
type / litres
Alkyl benzene (AB) / 1.9
6
Electrical connection
6.1
Supply voltage; fuse protection
V / A
1~ / N / PE 230V (50Hz) / C32A
6.2
Starting current with soft starter
A
28
6.3
Nominal power consumption at A2/W35 /
max. power consumption
3
kW
3.3 / 6.0
6.4
Nominal current at A2 / W35 / cos
ϕ
A / ---
18.0 / 0.8
6.5
Max. power consumption of compressor protection
(per compressor)
W
---
7
Complies with the European safety regulations
7
7. See CE declaration of conformity
8
Additional model features
8.1
Type of defrosting
Hot gas
8.2
Max. operating overpressure (heat sink)
bar
3.0
Содержание LA 14PMS
Страница 2: ......
Страница 30: ...FR 10 Fran ais 11...
Страница 35: ...www dimplex de A V Anhang Appendix Annexes 3 2 3 2 Last Load Charge...
Страница 36: ...A VI Anhang Appendix Annexes 3 3 3 3 Anschlussplan Circuit Diagram Sch ma lectrique...
Страница 42: ...A XII Anhang Appendix Annexes 5...
Страница 43: ...www dimplex de A XIII Anhang Appendix Annexes 5...