EN-10 452163.66.68 · FD 9705
www.dimplex.de
English
HPL 6S-TU(R)W
12 Device information
1
Type and order code
HPL 6S-TUW
HPL 6S-TURW
2
Design
Heat source
Air
Air
2.1
Model
Reversible with hydro tower
Reversible with hydro tower
2.2
Controller
Integrated (hydro tower)
Integrated (hydro tower)
2.3
Installation location
Haed pump / Hydro tower
Outdoors / Indoors
Outdoors / Indoors
2.4
Thermal energy metering
Integrated
Integrated
2.5
Performance levels
1
1
3
Operating limits
3.1
Heating water flow / return
1
°C
up to 60 ± 2 / from 18
up to 60 ± 2 / from 18
3.2
Air (heating)
°C
-22 to +35
-22 to +35
3.2
Cooling water flow
°C
-
+7 to +20
3.3
Air (cooling)
°C
-
+15 to +45
4
Flow
2
/ sound
4.1
Heating water flow
free compression
Nominal flow in accordance with EN 14511
at A7 / W35...30
m³/h / Pa
1.15 / 50200
1.15 / 50200
at A7 / W45...40
m³/h / Pa
1.08 / 54000
1.08 / 54000
at A7 / W55...47
m³/h / Pa
0.66 / 59500
0.66 / 59500
4.2
Minimum heating water flow rate
Heat pump circuit
m³/h / Pa
0.66 / 59500
0.66 / 59500
4.3
Cooling water flow rate / internal pressure differential
Nominal flow in accordance with EN 14511
A35 / W18...23
m³/h / Pa
0.8 / 58500
0.8 / 58500
Minimum cooling water flow rate
m³/h / Pa
0.8 / 58500
0.8 / 58500
4.4
Sound power level according to EN 12102
Normal operation / reduced operation
3
4
dB(A)
56 / 52
56 / 52
4.5
Sound pressure level at a distance of 10 m (air outlet side)
5
Normal operation / reduced operation
dB(A)
28 / 24
28 / 24
4.6
Air flow
Normal operation
m³/h
2700
2700
5
Dimensions, weight and filling quantities
5.1
Device dimensions without connections
H x W x L mm
945 X 1350 X 600
945 X 1350 X 600
5.2
Device connections for heating
inches
G 1“ external thread
G 1“ external thread
5.3
Weight of the transportable unit(s) incl. packaging
kg
185
185
5.4
Refrigerant / total filling weight
type/kg
R410A / 3.4
R410A / 3.4
5.5
GWP value / CO
2
equivalent
--- / t
2088 / 7
2088 / 7
5.6
Refrigeration circuit hermetically sealed
yes
yes
5.7
Lubricant / total filling quantity
type/litres
Polyolester (POE) / 0.7
Polyolester (POE) / 0.7
5.8
Volume of heating water in device
Litres
1.9
1.9
6
Electrical connection
6.1
Supply voltage / fusing / RCD type
3~/N/PE 400 V (50 Hz) / C10 A / A 3~/N/PE 400 V (50 Hz) / C10 A / A
6.2
Control voltage / fusing by WPM
1~/N/PE 230 V (50 Hz) / 4 AT
1~/N/PE 230 V (50 Hz) / 4 AT
6.3
Degree of protection according to EN 60529
IP 24
IP 24
6.4
Starting current limiter
No
No
6.5
Rotary field monitoring
No
No
6.6
Starting current
A
28
28
6.7
Nominal power consumption A2/W35 /
max. power consumption
kW
1.4 / 2.93
1.4 / 2.93
6.8
Nominal current A2 /W35 / cos
ϕ
A / ---
2.42 / 0.8
2.42 / 0.8
6.9
Power consumption of compressor protection
(per compressor)
W / ---
-
-
6.10 Power consumption of fan
W
< 125
< 125
Содержание HPL 6S-TURW
Страница 2: ......
Страница 14: ...DE 12 452163 66 68 FD 9705 www dimplex de Deutsch HPL 6S TU R W...
Страница 16: ...DE 14 452163 66 68 FD 9705 www dimplex de Deutsch HPL 6S TU R W...
Страница 28: ...EN 12 452163 66 68 FD 9705 www dimplex de English HPL 6S TU R W...
Страница 40: ...FR 12 452163 66 68 FD 9705 www dimplex de Fran ais HPL 6S TU R W...
Страница 53: ...www dimplex de 452163 66 68 FD 9705 A XIII HPL 6S TU R W Anhang Appendix Annexes...
Страница 54: ...A XIV 452163 66 68 FD 9705 www dimplex de Anhang Appendix Annexes HPL 6S TU R W...
Страница 55: ...www dimplex de 452163 66 68 FD 9705 A XV HPL 6S TU R W Anhang Appendix Annexes...