EN-12 452168.66.05 · FD 9512
www.dimplex.de
English
HPL 9S-TU(R)W - HPL 18S-TU(R)W
6
Electrical connection
6.1
Supply voltage / fusing / RCD type
3~/N/PE 400 V (50 Hz) /
C10 A / A
3~/N/PE 400 V (50 Hz) /
C10 A / A
3~/N/PE 400 V (50 Hz) /
C13 A / A
6.2
Control voltage / fusing by WPM
1~/N/PE 230 V (50 Hz) /
4 AT
1~/N/PE 230 V (50 Hz) /
4 AT
1~/N/PE 230 V (50 Hz) /
4 AT
6.3
Degree of protection according to EN 60529
IP 24
IP 24
IP 24
6.4
Starting current limiter
Soft starter
Soft starter
Soft starter
6.5
Rotary field monitoring
Yes
Yes
Yes
6.6
Starting current with soft starter
A
21
19
19
6.7
Nominal power consumption A2/W35 /
max. power consumption
4
kW
1,7 / 3,3
2,38 / 4,0
3,24 / 6,8
6.8
Nominal current A2 /W35 / cos
A / ---
3,1 / 0,8
4,3 / 0,8
5,9 / 0,8
6.9
Power consumption of compressor protection
(per compressor)
W / ---
70 / thermostatically
controlled
70 / thermostatically
controlled
70 / thermostatically
controlled
6.10 Power consumption of fan
W
< 150
< 200
< 250
7
Complies with the European safety regulations
9
9
9
8
Additional model features
8.1
Type of defrosting
Reverse circulation
Reverse circulation
Reverse circulation
8.2
Frost protection, condensate tray /
Water in device protected against freezing
10
Yes
Yes
Yes
8.3
Maximum operating pressure (heat sink)
bar
3.0
3.0
3.0
8.4
Energy efficiency class / energy efficiency (low temperature)
A++ / 177 %
A++ / 173 %
A++ / 186 %
8.5
Energy efficiency class / energy efficiency (mean temperature)
A++ / 127 %
A++ / 128 %
A++ / 133 %
9
Heat output COP
4
9.1
Heat output / COP
EN 14511
EN 14511
EN 14511
Performance level
1
2
1
2
1
2
at A-7 / W35
kW / ---
5,5 / 3,3
---
7,2 / 3,2
---
5,6 / 3,3
10,6 / 3,2
at A2 / W35
kW / ---
7,2 / 4,3
---
9,5 /
4.1(4,3)
11
---
7,3 / 4,3
12,3 / 3,9
(4,0)
11
at A7 / W35
kW / ---
8,4 / 4,9
---
11,3 / 4,8
---
8,4 / 5,0
---
at A7 / W45
kW / ---
8,2 / 3,8
---
10,8 / 3,9
---
8,1 / 3,9
---
at A7 / W55
kW / ---
8,0 / 3,0
---
10,0 / 3,1
---
7,7 / 3,2
---
at A10 / W35
kW / ---
8,9 / 5,3
---
12,0 / 5,1
---
8,8 / 5,4
---
10 Cooling capacity / COP
4
12
10.1 Cooling capacity / COP
EN 14511
EN 14511
EN 14511
Performance level
1
2
1
2
1
2
at A27 / W18
kW / ---
7,9 / 4,4
---
8,6 / 3,7
---
8,2 / 4,5
15,4 / 3,7
at A27 / W9
kW / ---
---
---
12,7 / 3,2
at A27 / W7
kW / ---
5,4 / 3,1
---
6,3 / 2,7
---
6,0 / 3,4
---
at A35 / W18
kW / ---
7,0 / 3,3
---
7,9 / 2,9
---
6,7 / 3,2
14,0 / 3,1
at A35 / W9
kW / ---
---
---
12,2 / 2,7
at A35 / W7
kW / ---
4,9 / 2,4
---
5,3 / 2,1
---
5,2 / 2,6
---
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45? to 60?.
2. Operation with 2 compressors
3. Operation with 1 compressor
4. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters, in particular
the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning
and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/W35: outside air tem-
perature 7 °C and heating water flow temperature 35 °C.
5. Standard nominal flow only possible with an electronically controlled circulating pump with actuation via heat pump manager.
6. The heat output and COP is reduced by approx. 5 % in lower operation
7. When the optional weather protection hood (accessory) is used, the sound pressure level in outlet direction is reduced by 3 dB(A).
8. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
9. See CE declaration of conformity
10.The heat circulating pump and the heat pump manager must always be ready for operation.
11.The coefficient of performance (COP) in partial load operation can be increased by selecting "energy-optimised heating operation" (natural defrosting)
12.The maximum sound power level under full load can increase by up to 5 dB(A).
Содержание HPL 12S-TURW
Страница 2: ......
Страница 16: ...DE 14 452168 66 05 FD 9512 www dimplex de Deutsch HPL 9S TU R W HPL 18S TU R W...
Страница 57: ...www dimplex de 452168 66 05 FD 9512 A XVII Anhang Appendix Annexes HPL 9S TU R W HPL 18S TU R W...
Страница 58: ...A XVIII 452168 66 05 FD 9512 www dimplex de Anhang Appendix Annexes HPL 9S TU R W HPL 18S TU R W...
Страница 59: ...www dimplex de 452168 66 05 FD 9512 A XIX Anhang Appendix Annexes HPL 9S TU R W HPL 18S TU R W...