![Dimensions Unlimited 12X16B3R4T Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/dimensions-unlimited/12x16b3r4t/12x16b3r4t_owners-manual_2502660004.webp)
Dimensions Unlimited
4
Specifications
Millennium Series
Standby Power Systems
12X16B3R4T, 12X20B3R4T,
12X25B3R4T, 12X30B3R4T,
12X36B3R4T
Environmentally Friendly,
Quiet, Reliable, AC Power
MODEL NUMBER
12X16
12X20
12X25
12X30
12X36
Output Power
(Watts Cont.)
1,600
2,000
2,500
3,000
3,600
Output Current
(Amps AC)
Up to 13
Up to 17
Up to 21
Up to 25
Up to 30
Peak Output
(Amps AC)
55
70
80
90
90
Output Rating:
(hp)
1
/
3
½
¾
1
1½
Input Current
(Amps DC)
Up to 160
Up to 200
Up to 250
Up to 300
Up to 360
Weight
(lbs.)
40
44
49
53
58
Dimensions
LxWxH (Inches)
15¾ x 11½ x 7¾
BATTERY CHARGER “B3”
3 step charger with automatic conditioning; Temperature compensated
output voltage; selectable between wet and sealed lead acid batteries;
selectable between small and large battery banks
Output Current
(Amps DC)
75
100
130
140
140
Input Current
(Amps AC)
Up to 16
Up to 21
Up to 26
Up to 28
Up to 28
TRANSFER RELAY “T”
Fail-safe shore power Transfer Relay
Current Rating
(Amps AC)
30
Transfer Time
(milliseconds)
Less than 16 typical
Output Voltage (VAC)
120 RMS ±5%
Output Frequency:
60 Hz ± 0.05%
Output Waveform:
Quasi-sine wave, with waveform stabilizer
Input Voltage: (VDC)
11 to 14
Operating Temperature:
-20° to 40° C (0° to 104° F)
Efficiency:
Up to 93%
Other Design Features:
•
Thermally controlled cooling fan.
•
Enclosed AC and DC cable connections with strain relief.
•
Built-in battery charger “B3” and transfer relay “T”
Remote Control Panel – “R4”:
•
LCD Display – Blue background, 16 white characters by
two lines with user-friendly messages.
•
Dimensions – W x H x D: 5.75” x 3.75” x 1.25”
•
Optional DC master disconnect switch control wire with
assembly panel 141315-1 only
Unit Protection:
•
Automatic electronic short
circuit/overload protection
•
Automatic high temperature
shutdown
•
Output circuit breakers
Battery Protection:
•
Automatic low battery shutdown
at 10.5 VDC (with in-rush delay)
•
Usage:
Any 120 VAC, 60 Hz single-phase products within the standby power system’s rating that does
not require a pure sine waveform.