Dimensions Unlimited 12X16B3R4T Скачать руководство пользователя страница 18

 

 

 

Dimensions Unlimited 

18 

 

g) 

 

 

 

 

 

This  indicates  that  the  charger  is  in  the  conditioning  mode.  Battery 

conditioning  is  automatically  performed  every  10

th

  complete  charge  cycles. 

The display also indicates the battery voltage and the amount of DC charge 

current flowing into the batteries. See tables II & III on page 15 for more 

information. 

 

 

h) 

 

 

 

 

This message is displayed when you press the “

Inverter & Reset – On/Off” 

button while the SPS is in the external power mode and the battery charger 

is activated. It indicates that the inverter is OFF and will not automatically 

turn  ON  when  external  power  is  removed.  Pressing  the  button  again  will 

result in message (j) below. This message will be displayed for ten seconds. 

 

 

i) 

 

 

This message is displayed when you press the 

“Inverter & Reset – On/Off”

 

button while the inverter is OFF and there is no external power connected 

to  the  SPS.  Pressing  this  button  again  will  turn  the  inverter  ON  and 

message (a) will appear. 

 

 

j) 

 

 

 

 

 

 

 

 

 

This message is displayed when you press the “

Inverter & Reset – On/Off”  

button while the SPS is in the external power mode and the battery charger 

is activated. It indicates that the inverter will automatically turn ON when the 

external power is removed. Pressing this button again will result in message 

(h) above. This message will be displayed for ten seconds. 

 

 

k) 

 

 

 

 

 

 

This message is displayed when you press the 

“Charger Draw – Set Input”

 

button. It indicates the battery charger input current limit setting. Pressing 

this button again will decrease the current limit. This is explained in more 

detail  in  section  7.1.3,  page  16.  This  message  will  be  displayed  for  ten 

seconds. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INVERTER-OFF 

PUSH FOR STANDBY

 

INVERT-STANDBY 
OVERRIDE BY CHGR 

CHGR- COND MODE 
xx.x VOLT, xxx AMP 

CHGR POWER DRAW 

LIMIT xx AMP AC 

INVERTER – OFF 

PUSH FOR ON 

Содержание 12X16B3R4T

Страница 1: ...d Company Dimensions Unlimited Inc DC to AC Standby Power Systems Owners Manual for Models 12X16B3R4T 12X20B3R4T 12X25B3R4T 12X30B3R4T 12X36B3R4T Including Options R1 LCD Remote Control Status Panel w...

Страница 2: ...llation 9 5 1 Tools Needed for Installation 9 5 2 System Components 9 5 3 Mounting the SPS 9 5 3 1 Chassis Bonding Lug 9 5 3 2 Temperature Compensation Sense Probe 9 5 3 3 Connecting the LCD Remote Co...

Страница 3: ...ounted in a location that may be exposed to rain or spray The Standby Power Systems should not be installed in a zero clearance enclosure Damage to the Standby Power Systems will occur if correct pola...

Страница 4: ...RELAY T Fail safe shore power Transfer Relay Current Rating Amps AC 30 Transfer Time milliseconds Less than 16 typical Output Voltage VAC 120 RMS 5 Output Frequency 60 Hz 0 05 Output Waveform Quasi si...

Страница 5: ...the transformer which steps the voltage up to 120 volts The unit has a Digital System Processor DSP to control the output voltage and frequency as the DC input voltage and or output load varies The s...

Страница 6: ...he plates of the battery cells The SPS has an automatic power sharing feature that automatically decreases the battery charger output so that the total AC input current draw by the SPS for both the AC...

Страница 7: ...put Output lead wires and DC field wiring compartment 3 Remote Control Panel Connector Connects to the LCD Remote Control Status Panel 4 Temperature Compensation Sensor Connector Connects to the remot...

Страница 8: ...ery charger 5 LCD Display Shows system status battery voltage and electrical current in both inverter and external power mode as well as shut down conditions 6 DC Master Disconnect switch control wire...

Страница 9: ...eing in the same airtight compartment If mounting the SPS on a vertical surface it is recommended that the front panel be pointing down whenever possible Locate the mounting holes on the chassis flang...

Страница 10: ...inches Heatsinks are available with the U option only or any 3600 watt inverter Front of the unit is to the right Heatsinks Figure 4 LCD Control panel footprint Assemblies 141255 2 or 141315 1 5 25 3...

Страница 11: ...model on table I cross reference the wire gauge and fuse size Table I Wire and Fusing Guide for 12VDC systems at 5 Voltage Drop at Full Output Figure 5 Inverter cable assembly 6 1 2 Charge Cable This...

Страница 12: ...f the battery bank a one time spark will occur when this final DC connection is made To determine the fuse size refer to section 6 1 1 6 1 3 Deep Cycle Batteries Do not use vehicle starting batteries...

Страница 13: ...recommended is Hubbell GFR 5352XX 20A or GFR 5252XX 15A Do not connect another source of AC power directly to the output of the SPS This will result in damage to the SPS that is not covered under warr...

Страница 14: ...put Under the hood Remote Temp Sense Red Black Charge Cable Red Connect the charging cables directly to the vehicle alternator whenever possible or to the OEM starting engine battery 2 pin Connector R...

Страница 15: ...tput Breaker AC Output AC Input 30A 20A Black wire Hot White wire Neutral Green wire Ground Black White Green Wire Wire Wire Hot Neutral Ground Install GFCI outlets Hubbell GFR 5352XX 20A or Hubbell G...

Страница 16: ...NDITIONING max BULK max ACCEPT max CONDITIONING max Less than 400 6 hrs 2 hrs 3 hrs 6 hrs 2 hrs 3 hrs Greater than 400 8 hrs 3 hrs 6 hrs 8 hrs 3 hrs 4 hrs If the bulk mode times out the charging proce...

Страница 17: ...the SPS The inverter is also turned OFF c When external AC power is connected to the SPS the three stage battery charger may be activated This indicates that the charge current limit has been set to 0...

Страница 18: ...n while the inverter is OFF and there is no external power connected to the SPS Pressing this button again will turn the inverter ON and message a will appear j This message is displayed when you pres...

Страница 19: ...troubleshooting table 7 2 1 Troubleshooting Chart MESSAGE PROBLEM POSSIBLE CAUSE 1 The SPS is not connected to the batteries or the battery voltage is below 9 volts DC Check the in line fuses for con...

Страница 20: ...battery Make sure that the DC cable connections are tight and clean and not shorted and that the proper wire gauge is used 9 Indicates that the charger has shut off due to high battery temperature 47...

Страница 21: ...verter On INVERTER xx xx WATT BATT xx x VOLTs CHGR OFF NO INPT INVERTER OFF Start battery charger Pass AC to loads No Yes No Yes No Yes Is current limit set at 0 amp CHGR OFF 0 AMP LIMIT SET Start bul...

Страница 22: ...D MODE xx x VOLT xxx AMP Has condition timer finished Stay in voltage conditioning Yes No Yes No Stay in acceptance mode CHGR ACCEPT MODE xx x VOLT xxx AMP No Yes Continued from previous page Has acce...

Страница 23: ...se that the goods or any component thereof manufactured by Dimensions Unlimited will be free from defects in workmanship from the date of purchase for the period listed on the product label provided s...

Страница 24: ...appliances and components found on RVs was something that I always had a desire to create I hope this resource makes your RV repairs easier as it has mine but please be careful and follow proper safe...

Отзывы: